Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break. The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve setting.
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-13A |
| Series | 1 |
| Capacity | 6 gpm |
| Capacity (metric) | 23 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi |
| Maximum Valve Leakage at 110 SUS (24 cSt) (metric) | 30 cc/min.@70 bar |
| Valve Hex Size | 7/8 in. |
| Valve Hex Size (metric) | 22,2 mm |
| Valve Installation Torque | 30 – 35 lbf ft |
| Valve Installation Torque (metric) | 41 – 47 Nm |
| Model Weight | 0.23 lb. |
| Model Weight (metric) | 0.10 kg. |
| Seal kit – Cartridge | Viton: 990010006 |
Control
| X | Not Adjustable |
Setting Range
| A | Replaceable Orifice .5 – 6 gpm (2 – 23 L/min.) |
| B | Permanent Orifice .5 – 6 gpm (2 – 23 L/min.) |
Seal Material
| N | Buna-N |
| V | Viton |
Material/Coating
| /AP | Stainless Steel, Passivated |
| /LH | Mild Steel, Zinc-Nickel |