Hydnet - the specialist in intelligent hydraulic systems
Contact
EVEC

Energy harvester from Sun Hydraulics

Description

This valve is a 2 port cartridge designed to convert hydraulic power from your application into electrical power. The valve accepts flow from Port 1 to Port 2 and outputs a 3-phase AC voltage signal.

Read more ▼
  • Power cable with mating connector is required (not included).
  • The valve exhibits up to 6 drops per hour of internal leakage into the electronics housing. The auxiliary drain port must be gravity fed and therefore remain at atmospheric pressure to prevent submersion of the electronics.
  • Valve must be installed in an upright or horizontal orientation. When installed horizontally, the collar should be positioned so that the drain is oriented downward.
  • This product can handle a maximum of 200 PSI (14 bar) at port 2 and is designed to harvest energy from fluid destined to return to tank.
  • Higher electrical loads and lower Port 2 pressure have a positive effect in reducing leakage.
  • In addition to elevated leakage, higher than rated pressures at Port 2 result in a reduction in the power output.
  • The electrical output is unregulated. Most applications will require external rectification/regulation.
  • Meets new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
  • Zinc-nickel plating standard for 1000-hour salt fog protection.
  • Only 3 pins of the Deutsch DT04-4P Connector are used. The 4th pin is unused. Please see pinout for reference.
  • Do not apply installation torque to the anodized aluminum motor housing.
  • This valve is CE compliant. It meets the requirements for RF Radiated Emissions (IEC 61000-6-4), Radiated Immunity (IEC 61000-4-3), and Magnetic Field Immunity (IEC 61000-4-8).
  • When torquing this cartridge into its cavity, a crow’s foot wrench or similar will be required since the motor housing precludes the use of a deep socket wrench.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-16A
Series 3
Number of Outputs 1
Vibration 33.3 Hz 6.8g Peak (Spec: S-367 Section 11.0)
Shock 49g Peak (Spec: S-367 Section 12.0)
Maximum Ambient Temperature 160 °F
Minimum Flow Rate to Harvest Energy (No Load) 10 gpm
Minimum Flow Rate to Harvest Energy (No Load) (metric) 40 L/min.
Maximum Flow Rate 50 gpm
Maximum Flow Rate (metric) 200 L/min.
External Drain Port Interface 4mm PTC Connector
External Drain Port Leakage Rate 6 drops/hr
Output Voltage – Maximum Flow Rate 30 VDC (After Rectification)
Termination Deutsch DT04-4P
Maximum Load Current 3A
Maximum Operating Pressure (Port 2) 200 psi
Maximum Operating Pressure (Port 2) (metric) 14 bar
Duty Cycle Rating 100 %
Connector 4-Pin Deutsch (3 Phase AC Output)
Valve Hex Size 1 1/4 in.
Valve Hex Size (metric) 31,8 mm
Valve Installation Torque 150 – 160 lbf ft
Valve Installation Torque (metric) 203 – 217 Nm
Model Weight 2.38 lb.
Model Weight (metric) 1.08 kg.
IP Rating IP69K
U.S. Patent # 11,988,185
Seal kit – Cartridge Viton: 990316006

Configuration Options

Control

X Standard

Functional Setting Range

X No Check

Seal Material

V Viton
Cavity: T-16A
Downloads
PDFSTP
Possible variants

EVECXXV