Hydnet - the specialist in intelligent hydraulic systems
Contact
XBBA

Description

This cavity plug allows ports 1 and 3 to remain open and blocks port 2.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-2A
Series 2
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Valve Hex Size 1 1/8 in.
Valve Hex Size (metric) 28,6 mm
Valve Installation Torque 45 – 50 lbf ft
Valve Installation Torque (metric) 61 – 68 Nm
Seal kit – Cartridge Viton: 990202006
Model Weight 0.41 lb.
Model Weight (metric) 0.18 kg.

Configuration Options

Control

X

Adjustment Range

X

Seal Material

N Buna-N
V Viton

Material/Coating

/AP Stainless Steel, Passivated
From Cavity to Cavity: Fluid controls #173 to T-11A
Cavity: T-2A
Nominal Capacity: 30 gpm (120 lpm)