Description

This cavity plug mounts flush with the cavity and allows all ports to remain open.

Read more ▼

Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-162A
Series 0
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Port Configuration 2 Port
Valve Internal Hex Size 5/16 in.
Valve Internal Hex Size (metric) 8 mm
Valve Installation Torque 20 – 25 lbf ft
Valve Installation Torque (metric) 27 – 33 Nm
Seal kit – Cartridge Viton: 990162006
Model Weight 0.03 lb.
Model Weight (metric) 0.02 kg.