4-way directional valve from Sun Hydraulics
This solenoid-operated, 4-way, 2-position cartridge is a direct-acting, balanced spool directional valve. The transition between positions is closed. The closed transition greatly reduces the loss of oil when shifting which can be of particular importance in pilot control circuits.
The position switch provides confirmation that the valve is in the spring biased position. Click Here for the position sensor pin diagram
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-31A |
| Series | 1 |
| Capacity | 8 gpm |
| Capacity (metric) | 30 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 in³/min.@3000 psi |
| Maximum Valve Leakage at 110 SUS (24 cSt) (metric) | 160 cc/min.@210 bar |
| Response Time – Typical | 50 ms |
| Switching Frequency | 15,000 max. cycles/hr |
| Solenoid Tube Diameter | .75 in. |
| Solenoid Tube Diameter (metric) | 19 mm |
| Valve Hex Size | 7/8 in. |
| Valve Hex Size (metric) | 22,2 mm |
| Valve Installation Torque | 30 – 35 lbf ft |
| Valve Installation Torque (metric) | 41 – 47 Nm |
| Model Weight | 2.14 lb. |
| Model Weight (metric) | 0.97 kg. |
| Seal kit – Cartridge | Viton: 990431006 |
| Supply Voltage | 20-30 VDC |
| Operating Temperature Range | -25 to 80 °C |
| Vibration | ≥ 50g, 0-500 impulses/sec |
| Shock | >50 g, 1ms |
| Reverse Polarity Protection | Yes |
| Maximum Output Load | ≤ 400 mA, Duty Ratio 100% |
| Short Circuit Protection | Yes, Load Short Unlimited |
| Turn On Time | ≤ 25 ms |
| Hysteresis | ≤ .002 in. |
| Thermal Shift – 0 to 80 °C ≤ ± | .004 in. |
| Thermal Shift – 0 to 80 °C ≤ ± (metric) | 0,1 mm |
| EMC | DIN EN 61000-6-1/2/3/4 |
| Connector | M12 X 1 (4) Pin |
| Connector Environment Rating | IP65 |
Spool Configuration
| C ★ | Closed, Shift to Through |
| X ★ | Cross, Shift to Through |
| A | A to T, Shift to Through |
| B | B to T, Shift to Through |
| J | Open, Shift to Through |
| L | Cross, Shift to P to A, B and T Blocked |
| S | Regen, Shift to Through |
| T | Tandem, Shift to Through |
| W | A and B Bleed to T, Shift to Through |
| Z | Motor, Shift to Through |
Seal Material
| N | Buna-N |
| V | Viton |
Coil
| 211 | DIN 43650-Form A, 115 VAC |
| 212 | DIN 43650-Form A, 12 VDC |
| 212N | DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes |
| 214N | DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes |
| 223 | DIN 43650-Form A, 230 VAC |
| 224 | DIN 43650-Form A, 24 VDC |
| 224N | DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes |
| 228 | DIN 43650-Form A, 28 VDC |
| 812 | Metri-Pack, 12 VDC |
| 912 | Deutsch DT04-2P, 12 VDC |
| 912N | Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes |
| 924 | Deutsch DT04-2P, 24 VDC |
| 924N | Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes |