Hydnet - the specialist in intelligent hydraulic systems
Contact
DLDFS

2-way directional valve from Sun Hydraulics

Description

This solenoid-operated 2-way, 2-position cartridge is a direct-acting, balanced spool valve with a soft shift feature. The soft shift feature reduces system shock due to valve actuation. The valve is available in either a normally open or normally closed configuration.

This valve is designed to be used with 740 and 747 Series coils.

Read more ▼
  • The soft shift cartridge is interchangeable with the standard cartridge, however, the performance limits are lower.
  • The soft shift feature can reduce shock due to valve actuation but should not be counted upon in applications where timing is critical. If you need accurate ramping or timing control, consider Sun’s electro-proportional valves.
  • The soft shift feature results in an increase in response time over Sun’s standard solenoid. Response time is dependent on flow, pressure, coil voltage, oil viscosity and ambient temperature.
  • For consistent soft shift performance, port 1 should be at a positive pressure.
  • The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
  • This valve is direct actuated and requires no minimum hydraulic pressure for operation.
  • All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
  • This cartridge utilizes both 740 Series high-power and 747 Series hazardous location coils.
  • This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • The solenoid’s unique magnetic design results in a high efficiency solenoid, yielding high spool actuating force per Watt expended, leading to reliable valve shifting.
  • Coils can be mounted on the tube in either direction.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-13A
Series 1
Capacity 12 gpm
Capacity (metric) 45 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@3000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) (metric) 80 cc/min.@210 bar
Manual Override Force Requirement 5 lbs/1000 psi @ Port 1
Manual Override Force Requirement (metric) 33 N/100 bar @ Port 1
Manual Override Stroke .10 in.
Manual Override Stroke (metric) 2,5 mm
Response Time – Typical 50 ms
Switching Frequency 15,000 max. cycles/hr
Solenoid Tube Diameter .63 in.
Solenoid Tube Diameter (metric) 16 mm
Valve Hex Size 7/8 in.
Valve Hex Size (metric) 22,2 mm
Valve Installation Torque 30 – 35 lbf ft
Valve Installation Torque (metric) 41 – 47 Nm
Model Weight .50 lb
Model Weight (metric) 0,25 kg
Seal kit – Cartridge Viton: 990413006

Configuration Options

Poppet Configuration

C Normally Closed
H Normally Open

Seal Material

N Buna-N
V Viton

Coil

211 DIN 43650-Form A, 115 VAC
212 DIN 43650-Form A, 12 VDC
212D DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes
214 DIN 43650-Form A, 14 VDC
214D DIN 43650-Form A, 14 VDC, with transient voltage suppression (TVS) diodes
223 DIN 43650-Form A, 230 VAC
224 DIN 43650-Form A, 24 VDC
224D DIN 43650-Form A, 24 VDC, with transient voltage suppression (TVS) diodes
228 DIN 43650-Form A, 28 VDC
228D DIN 43650-Form A, 28 VDC, with transient voltage suppression (TVS) diodes
612 AMP Junior Timer, 12 VDC
612D AMP Junior Timer, 12 VDC, with transient voltage suppression (TVS) diodes
614 AMP Junior Timer, 14 VDC
614D AMP Junior Timer, 14 VDC, with transient voltage suppression (TVS) diodes
624 AMP Junior Timer, 24 VDC
624D AMP Junior Timer, 24 VDC, with transient voltage suppression (TVS) diodes
628 AMP Junior Timer, 28 VDC
628D AMP Junior Timer, 28 VDC, with transient voltage suppression (TVS) diodes
712 Twin Lead, 12 VDC
712D Twin Lead, 12 VDC, with transient voltage suppression (TVS) diodes
714 Twin Lead, 14 VDC
714D Twin Lead, 14 VDC, with transient voltage suppression (TVS) diodes
724 Twin Lead, 24 VDC
724D Twin Lead, 24 VDC, with transient voltage suppression (TVS) diodes
728 Twin Lead, 28 VDC
728D Twin Lead, 28 VDC, with transient voltage suppression (TVS) diodes
812 Metri-Pack, 12 VDC
812D Metri-Pack, 12 VDC, with transient voltage suppression (TVS) diodes
814 Metri-Pack, 14 VDC
814D Metri-Pack, 14 VDC, with transient voltage suppression (TVS) diodes
824 Metri-Pack, 24 VDC
824D Metri-Pack, 24 VDC, with transient voltage suppression (TVS) diodes
828 Metri-Pack, 28 VDC
912 Deutsch DT04-2P, 12 VDC
912D Deutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodes
914 Deutsch DT04-2P, 14 VDC
914D Deutsch DT04-2P, 14 VDC, with transient voltage suppression (TVS) diodes
924 Deutsch DT04-2P, 24 VDC
924D Deutsch DT04-2P, 24 VDC, with transient voltage suppression (TVS) diodes
928 Deutsch DT04-2P, 28 VDC
928D Deutsch DT04-2P, 28 VDC, with transient voltage suppression (TVS) diodes
JM24BD Explosion Proof, Metric (M20 X 1.5), 24 VDC, 180 Degree, CSA and ATEX Certification
JM24CD Explosion Proof, Metric (M20 X 1.5), 24 VDC, 90 Degree, CSA and ATEX Certification
JN24BD Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 180 Degree, CSA and ATEX Certification
JN24CD Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 90 Degree, CSA and ATEX Certification
Cavity: T-13A
Nominal Capacity: 12 gpm (45 lpm )
Downloads
PDFSTP
Possible variants

DLDFSCN, DLDFSHN, DLDFSCV, DLDFSHV