Hydnet - the specialist in intelligent hydraulic systems
Contact
SCEB

Sequence valve from Sun Hydraulics

Description

Atmospherically referenced, direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of this sequence valve controls the pressure at port 1 relative to the atmospheric vent.

Read more ▼
  • Suitable for use in load holding applications.
  • Atmospherically referenced valves should only be used where it is impossible have a drain connection. Over time, the atmospherically referenced valves may leak externally or allow moisture into the spring chamber.
  • Approximately 1 drop (0,07 cc) of fluid will pass into the vented spring chamber every 4000 cycles.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-5A
Series 2
Capacity 30 gpm
Capacity (metric) 120 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at 2 in³/min.
Factory Pressure Settings Established at (metric) 30 cc/min.
Maximum Valve Leakage at Reseat 10 drops/min.
Maximum Valve Leakage at Reseat (metric) 0,7 cc/min.
Check Cracking Pressure 25 psi
Check Cracking Pressure (metric) 1,7 bar
Response Time – Typical 2 ms
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 1 1/8 in.
Valve Hex Size (metric) 28,6 mm
Valve Installation Torque 45 – 50 lbf ft
Valve Installation Torque (metric) 61 – 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.81 lb.
Model Weight (metric) 0.37 kg.
Seal kit – Cartridge Viton: 990203006

Configuration Options

Control

C Tamper Resistant – Factory Set
L Standard Screw Adjustment
K Handknob

Adjustment Range

A 500 – 3000 psi (35 – 210 bar), 1000 psi (70 bar) Standard Setting
B 300 – 1500 psi (20 – 105 bar), 1000 psi (70 bar) Standard Setting
C 2000 – 6000 psi (140 – 420 bar), 2000 psi (140 bar) Standard Setting
D 200 – 800 psi (14 – 55 bar), 400 psi (28 bar) Standard Setting
E 100 – 400 psi (7 – 28 bar), 200 psi (14 bar) Standard Setting
W 800 – 4500 psi (55 – 315 bar), 1000 psi (70 bar) Standard Setting

Seal Material

N Buna-N
V Viton
Cavity: T-5A
Nominal Capacity: 30 gpm (120 lpm)
Downloads
PDFSTP
Possible variants

SCEBCAN, SCEB-CAN, SCEBCAV, SCEB-CAV, SCEBCBN, SCEB-CBN, SCEBCBV, SCEB-CBV, SCEBCCN, SCEB-CCN, SCEBCCV, SCEB-CCV, SCEBCDN, SCEB-CDN, SCEBCDV, SCEB-CDV, SCEBCEN, SCEB-CEN, SCEBCEV, SCEB-CEV, SCEBCWN, SCEB-CWN, SCEBCWV, SCEB-CWV, SCEBKAN, SCEB-KAN, SCEBKAV, SCEB-KAV, SCEBKBN, SCEB-KBN, SCEBKBV, SCEB-KBV, SCEBKCN, SCEB-KCN, SCEBKCV, SCEB-KCV, SCEBKDN, SCEB-KDN, SCEBKDV, SCEB-KDV, SCEBKEN, SCEB-KEN, SCEBKEV, SCEB-KEV, SCEBKWN, SCEB-KWN, SCEBKWV, SCEB-KWV, SCEBLAN, SCEB-LAN, SCEBLAV, SCEB-LAV, SCEBLBN, SCEB-LBN, SCEBLBV, SCEB-LBV, SCEBLCN, SCEB-LCN, SCEBLCV, SCEB-LCV, SCEBLDN, SCEB-LDN, SCEBLDV, SCEB-LDV, SCEBLEN, SCEB-LEN, SCEBLEV, SCEB-LEV, SCEBLWN, SCEB-LWN, SCEBLWV, SCEB-LWV