Hydnet - the specialist in intelligent hydraulic systems
Contact
PRTS

Pressure reducing/relieving valve from Sun Hydraulics

Description

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet port (Port 2) to a constant reduced pressure at Port 1, with a relief function from Port 1 to tank (Port 3). The valve is biased to the relieving mode. Energizing the coil connects Port 2 to Port 1. Increasing the current to the coil will proportionally increase the reduced pressure at Port 1. If pressure at Port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is closed in the transition between reducing and relieving resulting in very low consumption of oil.

Read more ▼
  • The solenoid tube assembly is fatigue rated for 3000 psi (210 bar) service.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio.
  • This valve features a filter installed on port 2 with a micron rating of 280.
  • Specified leakage is out of port 3, with 3000 psi (210 bar) at port 2 and port 1 deadheaded.
  • For best performance, an amplifier with current sensing and adjustable dither should be used. Recommended dither is 200 Hz.
  • This valve is available with a push-type manual override. There is no upper limit to the pressure setting when using the M control. The more force you exert on the manual override, the higher the resulting pressure. This option is also rated for 3000 psi (210 bar).
  • The cartridge installation torque of 22 lbf ft (30 Nm) should be respected for best performance.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • The metal coil nut is a functional feature of the valve and should be correctly installed for proper performance of the valve.
  • Coil connector options offer ratings up to IP67. See individual coil product pages for details.
  • Coils can be mounted on the tube in either direction.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity SC-08-03
Series 0C
Capacity 1 gpm
Capacity (metric) 4 L/min.
Maximum Operating Pressure 3000 psi
Maximum Operating Pressure (metric) 210 bar
Typical Valve Leakage at 110 SUS (24cSt) 0.3 in³/min.@3000 psi
Typical Valve Leakage at 110 SUS (24cSt) (metric) 4,5 mL/min.@210 bar
Solenoid Tube Diameter .51 in.
Valve Hex Size 7/8 in.
Valve Hex Size (metric) 22,2 mm
Coil Nut Torque 3.5 – 3.9 lbf ft
Coil Nut Torque (metric) 4,8 – 5,3 Nm
Valve Installation Torque 21 – 23 lbf ft
Valve Installation Torque (metric) 28 – 31 Nm
Model Weight 0.35 lb.
Model Weight (metric) 0.16 kg.

Configuration Options

Control

M
X

Adjustment Range

D 0 – 435 psi
E 0 – 290 psi

Seal Material

N Buna-N

Coil

212 DIN 43650-Form A, 12 VDC
224 DIN 43650-Form A, 24 VDC
912D Deutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodes
924D Deutsch DT04-2P, 24 VDC, with transient voltage suppression (TVS) diodes
Cavity: SC-08-03
Nominal Capacity: 4 lpm (1 gpm)
Downloads
PDFSTP
Possible variants

PRTSMDN212, PRTS-MDN212, PRTSMDN224, PRTS-MDN224, PRTSMDN912D, PRTS-MDN912D, PRTSMEN212, PRTS-MEN212, PRTSMEN224, PRTS-MEN224, PRTSMEN912D, PRTS-MEN912D, PRTSMEN924D, PRTS-MEN924D, PRTSXDN212, PRTS-XDN212, PRTSXDN224, PRTS-XDN224, PRTSXDN924D, PRTS-XDN924D, PRTSXEN212, PRTS-XEN212, PRTSXEN224, PRTS-XEN224, PRTSXEN924D, PRTS-XEN924D