Hydnet - the specialist in intelligent hydraulic systems
Contact
PSFT

Pressure reducing/relieving valve from Sun Hydraulics

Description

The direct-acting reducer/reliever main section is meant to act as an interface between a low flow pressure source at port 4 and a circuit with higher flow requirements. The valve will reduce a high primary pressure at the inlet (port 2) to a reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

The valve incorporates a damped construction for stable operation allowing the use of high reduced pressure.

Read more ▼
  • The valve is biased to the relieving mode with a 100 psi (7 bar) spring. Pressure at port 4 is directly added to the setting of the valve once this threshold is exceeded. For example, 1000 psi (70 bar) at port 4 will result in a setting of 900 psi (63 bar) at port 1.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-22A
Series 2
Capacity 20 gpm
Capacity (metric) 80 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at blocked control port (dead headed)
Maximum Valve Leakage at 110 SUS (24 cSt) 3 in³/min.@1000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) (metric) 50 cc/min.@70 bar
Valve Hex Size 1 1/8 in.
Valve Hex Size (metric) 28,6 mm
Valve Installation Torque 45 – 50 lbf ft
Valve Installation Torque (metric) 61 – 68 Nm
Model Weight 0.67 lb.
Model Weight (metric) 0.30 kg.
Seal kit – Cartridge Viton: 990022006

Configuration Options

Control

X Not Adjustable

Bias Pressure

F 100 psi (7 bar)

Seal Material

N Buna-N
V Viton
E EPDM
Cavity: T-22A
Nominal Capacity: 80 lpm (20 gpm)
Downloads
PDFSTP
Possible variants

PSFTXFE, PSFT-XFE, PSFTXFN, PSFT-XFN, PSFTXFV, PSFT-XFV