Hydnet - the specialist in intelligent hydraulic systems
Contact
RSJC

Sequence valve from Sun Hydraulics

Description

Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence), up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in the return line.

Read more ▼
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Not suitable for use in load holding applications due to spool leakage.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-19A
Series 4
Capacity 120 gpm
Capacity (metric) 480 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at 4 gpm
Factory Pressure Settings Established at (metric) 15 L/min.
Control Pilot Flow 15 – 20 in³/min.
Control Pilot Flow (metric) 0,25 – 0,33 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@1000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) (metric) 80 cc/min.@70 bar
Response Time – Typical 10 ms
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 1 5/8 in.
Valve Hex Size (metric) 41,3 mm
Valve Installation Torque 350 – 375 lbf ft
Valve Installation Torque (metric) 474 – 508 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 3.17 lb.
Model Weight (metric) 1.44 kg.
Seal kit – Cartridge Viton: 990019006

Configuration Options

Control

L ★ Standard Screw Adjustment
C Tamper Resistant – Factory Set
K Handknob
Y Tri-Grip Handknob

Adjustment Range

A ★ 100 – 3000 psi (7 – 210 bar), 1000 psi (70 bar) Standard Setting
W ★ 150 – 4500 psi (10,5 – 315 bar), 1000 psi (70 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 1000 psi (70 bar) Standard Setting
C 150 – 6000 psi (10,5 – 420 bar), 1000 psi (70 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 400 psi (28 bar) Standard Setting

Seal Material

N ★ Buna-N
V Viton

Material/Coating

/LH Mild Steel, Zinc-Nickel
Cavity: T-19A
Nominal Capacity: 120 gpm (480 lpm )
Downloads
PDFSTP
Possible variants

RSJC8DN, RSJC-8DN, RSJC8DV, RSJC-8DV, RSJC8WN, RSJC-8WN, RSJC8WV, RSJC-8WV, RSJCCAN, RSJC-CAN, RSJCCAV, RSJC-CAV, RSJCCBN, RSJC-CBN, RSJCCBV, RSJC-CBV, RSJCCCN, RSJC-CCN, RSJCCCV, RSJC-CCV, RSJCCDN, RSJC-CDN, RSJCCDV, RSJC-CDV, RSJCCEN, RSJC-CEN, RSJCCEV, RSJC-CEV, RSJCCWN, RSJC-CWN, RSJCCWV, RSJC-CWV, RSJCKAN, RSJC-KAN, RSJCKAV, RSJC-KAV, RSJCKBN, RSJC-KBN, RSJCKBV, RSJC-KBV, RSJCKCN, RSJC-KCN, RSJCKCV, RSJC-KCV, RSJCKDN, RSJC-KDN, RSJCKDV, RSJC-KDV, RSJCKEN, RSJC-KEN, RSJCKEV, RSJC-KEV, RSJCKWN, RSJC-KWN, RSJCKWV, RSJC-KWV, RSJCLAN, RSJC-LAN, RSJCLAN/LH, RSJC-LAN/LH, RSJCLAV, RSJC-LAV, RSJCLAV/LH, RSJC-LAV/LH, RSJCLBN, RSJC-LBN, RSJCLBN/LH, RSJC-LBN/LH, RSJCLBV, RSJC-LBV, RSJCLBV/LH, RSJC-LBV/LH, RSJCLCN, RSJC-LCN, RSJCLCN/LH, RSJC-LCN/LH, RSJCLCV, RSJC-LCV, RSJCLCV/LH, RSJC-LCV/LH, RSJCLDN, RSJC-LDN, RSJCLDN/LH, RSJC-LDN/LH, RSJCLDV, RSJC-LDV, RSJCLDV/LH, RSJC-LDV/LH, RSJCLEN, RSJC-LEN, RSJCLEN/LH, RSJC-LEN/LH, RSJCLEV, RSJC-LEV, RSJCLEV/LH, RSJC-LEV/LH, RSJCLWN, RSJC-LWN, RSJCLWN/LH, RSJC-LWN/LH, RSJCLWV, RSJC-LWV, RSJCLWV/LH, RSJC-LWV/LH, RSJCYAN, RSJC-YAN, RSJCYAV, RSJC-YAV, RSJCYBN, RSJC-YBN, RSJCYBV, RSJC-YBV, RSJCYCN, RSJC-YCN, RSJCYCV, RSJC-YCV, RSJCYDN, RSJC-YDN, RSJCYDV, RSJC-YDV, RSJCYEN, RSJC-YEN, RSJCYEV, RSJC-YEV, RSJCYWN, RSJC-YWN, RSJCYWV, RSJC-YWV