Hydnet - the specialist in intelligent hydraulic systems
Contact
RSBC

Sequence valve from Sun Hydraulics

Description

Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence), up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in the return line.

Read more ▼
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Minimum setting is 75 psi (5 bar) for all spring ranges.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Not suitable for use in load holding applications due to spool leakage.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-163A
Series 0
Capacity 7.5 gpm
Capacity (metric) 30 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at 4 gpm
Factory Pressure Settings Established at (metric) 15 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 2 in³/min.
Maximum Valve Leakage at 110 SUS (24 cSt) (metric) 30 cc/min.
Response Time – Typical 10 ms
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 3/4 in.
Valve Hex Size (metric) 19,1 mm
Valve Installation Torque 20 – 25 lbf ft
Valve Installation Torque (metric) 27 – 33 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.25 lb.
Model Weight (metric) 0.11 kg.
Seal kit – Cartridge Viton: 990163006

Configuration Options

Control

L ★ Standard Screw Adjustment
C Tamper Resistant – Factory Set
K Handknob

Adjustment Range

A ★ 75 – 3000 psi (5 – 210 bar), 1000 psi (70 bar) Standard Setting
W ★ 75 – 4500 psi (5 – 315 bar), 1000 psi (70 bar) Standard Setting
B 75 – 1500 psi (5 – 105 bar), 1000 psi (70 bar) Standard Setting
C 75 – 6000 psi (5 – 420 bar), 1000 psi (70 bar) Standard Setting
N 75 – 800 psi (5 – 55 bar), 400 psi (28 bar) Standard Setting
Q 75 – 400 psi (5 – 28 bar), 200 psi (14 bar) Standard Setting

Seal Material

N ★ Buna-N
V Viton
E EPDM

Material/Coating

/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
Cavity: T-163A
Nominal Capacity: 30 lpm (7.5 gpm)
Downloads
PDFSTP
Possible variants

RSBCCAE, RSBC-CAE, RSBCCAN, RSBC-CAN, RSBCCAN/AP, RSBC-CAN/AP, RSBCCAN/LH, RSBC-CAN/LH, RSBCCAV, RSBC-CAV, RSBCCAV/AP, RSBC-CAV/AP, RSBCCAV/LH, RSBC-CAV/LH, RSBCCBE, RSBC-CBE, RSBCCBN, RSBC-CBN, RSBCCBN/AP, RSBC-CBN/AP, RSBCCBN/LH, RSBC-CBN/LH, RSBCCBV, RSBC-CBV, RSBCCBV/AP, RSBC-CBV/AP, RSBCCBV/LH, RSBC-CBV/LH, RSBCCCE, RSBC-CCE, RSBCCCN, RSBC-CCN, RSBCCCN/AP, RSBC-CCN/AP, RSBCCCN/LH, RSBC-CCN/LH, RSBCCCV, RSBC-CCV, RSBCCCV/AP, RSBC-CCV/AP, RSBCCCV/LH, RSBC-CCV/LH, RSBCCNE, RSBC-CNE, RSBCCNN, RSBC-CNN, RSBCCNN/AP, RSBC-CNN/AP, RSBCCNN/LH, RSBC-CNN/LH, RSBCCNV, RSBC-CNV, RSBCCNV/AP, RSBC-CNV/AP, RSBCCNV/LH, RSBC-CNV/LH, RSBCCQE, RSBC-CQE, RSBCCQN, RSBC-CQN, RSBCCQN/AP, RSBC-CQN/AP, RSBCCQN/LH, RSBC-CQN/LH, RSBCCQV, RSBC-CQV, RSBCCQV/AP, RSBC-CQV/AP, RSBCCQV/LH, RSBC-CQV/LH, RSBCCWE, RSBC-CWE, RSBCCWN, RSBC-CWN, RSBCCWN/AP, RSBC-CWN/AP, RSBCCWN/LH, RSBC-CWN/LH, RSBCCWV, RSBC-CWV, RSBCCWV/AP, RSBC-CWV/AP, RSBCCWV/LH, RSBC-CWV/LH, RSBCKAE, RSBC-KAE, RSBCKAN, RSBC-KAN, RSBCKAV, RSBC-KAV, RSBCKBE, RSBC-KBE, RSBCKBN, RSBC-KBN, RSBCKBV, RSBC-KBV, RSBCKCE, RSBC-KCE, RSBCKCN, RSBC-KCN, RSBCKCV, RSBC-KCV, RSBCKNE, RSBC-KNE, RSBCKNN, RSBC-KNN, RSBCKNV, RSBC-KNV, RSBCKQE, RSBC-KQE, RSBCKQN, RSBC-KQN, RSBCKQV, RSBC-KQV, RSBCKWE, RSBC-KWE, RSBCKWN, RSBC-KWN, RSBCKWV, RSBC-KWV, RSBCLAE, RSBC-LAE, RSBCLAN, RSBC-LAN, RSBCLAN/AP, RSBC-LAN/AP, RSBCLAN/LH, RSBC-LAN/LH, RSBCLAV, RSBC-LAV, RSBCLAV/AP, RSBC-LAV/AP, RSBCLAV/LH, RSBC-LAV/LH, RSBCLBE, RSBC-LBE, RSBCLBN, RSBC-LBN, RSBCLBN/AP, RSBC-LBN/AP, RSBCLBN/LH, RSBC-LBN/LH, RSBCLBV, RSBC-LBV, RSBCLBV/AP, RSBC-LBV/AP, RSBCLBV/LH, RSBC-LBV/LH, RSBCLCE, RSBC-LCE, RSBCLCN, RSBC-LCN, RSBCLCN/AP, RSBC-LCN/AP, RSBCLCN/LH, RSBC-LCN/LH, RSBCLCV, RSBC-LCV, RSBCLCV/AP, RSBC-LCV/AP, RSBCLCV/LH, RSBC-LCV/LH, RSBCLNE, RSBC-LNE, RSBCLNN, RSBC-LNN, RSBCLNN/AP, RSBC-LNN/AP, RSBCLNN/LH, RSBC-LNN/LH, RSBCLNV, RSBC-LNV, RSBCLNV/AP, RSBC-LNV/AP, RSBCLNV/LH, RSBC-LNV/LH, RSBCLQE, RSBC-LQE, RSBCLQN, RSBC-LQN, RSBCLQN/AP, RSBC-LQN/AP, RSBCLQN/LH, RSBC-LQN/LH, RSBCLQV, RSBC-LQV, RSBCLQV/AP, RSBC-LQV/AP, RSBCLQV/LH, RSBC-LQV/LH, RSBCLWE, RSBC-LWE, RSBCLWN, RSBC-LWN, RSBCLWN/AP, RSBC-LWN/AP, RSBCLWN/LH, RSBC-LWN/LH, RSBCLWV, RSBC-LWV, RSBCLWV/AP, RSBC-LWV/AP, RSBCLWV/LH, RSBC-LWV/LH