Hydnet - the specialist in intelligent hydraulic systems
Contact
SQJB

Sequence valve from Sun Hydraulics

Description

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

Read more ▼
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-19A
Series 4
Capacity 120 gpm
Capacity (metric) 480 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at Kick down point
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.
Maximum Valve Leakage at 110 SUS (24 cSt) (metric) 80 cc/min.
Response Time – Typical 25 ms
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 1 5/8 in.
Valve Hex Size (metric) 41,3 mm
Valve Installation Torque 350 – 375 lbf ft
Valve Installation Torque (metric) 474 – 508 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 3.16 lb.
Model Weight (metric) 1.43 kg.
Seal kit – Cartridge Viton: 990019006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment

Adjustment Range

A 100 – 3000 psi (7 – 210 bar), 1000 psi (70 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 1000 psi (70 bar) Standard Setting
C 150 – 6000 psi (10,5 – 420 bar), 1000 psi (70 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 400 psi (28 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
W 150 – 4500 psi (10,5 – 315 bar), 1000 psi (70 bar) Standard Setting

Seal Material

N Buna-N
V Viton
Cavity: T-19A
Nominal Capacity: 120 gpm (480 lpm )
Downloads
PDFSTP
Possible variants

SQJBCAN, SQJB-CAN, SQJBCAV, SQJB-CAV, SQJBCBN, SQJB-CBN, SQJBCBV, SQJB-CBV, SQJBCCN, SQJB-CCN, SQJBCCV, SQJB-CCV, SQJBCDN, SQJB-CDN, SQJBCDV, SQJB-CDV, SQJBCEN, SQJB-CEN, SQJBCEV, SQJB-CEV, SQJBCWN, SQJB-CWN, SQJBCWV, SQJB-CWV, SQJBKAN, SQJB-KAN, SQJBKAV, SQJB-KAV, SQJBKBN, SQJB-KBN, SQJBKBV, SQJB-KBV, SQJBKCN, SQJB-KCN, SQJBKCV, SQJB-KCV, SQJBKDN, SQJB-KDN, SQJBKDV, SQJB-KDV, SQJBKEN, SQJB-KEN, SQJBKEV, SQJB-KEV, SQJBKWN, SQJB-KWN, SQJBKWV, SQJB-KWV, SQJBLAN, SQJB-LAN, SQJBLAV, SQJB-LAV, SQJBLBN, SQJB-LBN, SQJBLBV, SQJB-LBV, SQJBLCN, SQJB-LCN, SQJBLCV, SQJB-LCV, SQJBLDN, SQJB-LDN, SQJBLDV, SQJB-LDV, SQJBLEN, SQJB-LEN, SQJBLEV, SQJB-LEV, SQJBLWN, SQJB-LWN, SQJBLWV, SQJB-LWV