Hydnet - the specialist in intelligent hydraulic systems
Contact
SQFB

Sequence valve from Sun Hydraulics

Description

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

Read more ▼
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-2A
Series 2
Capacity 30 gpm
Capacity (metric) 120 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at Kick down point
Maximum Valve Leakage at 110 SUS (24 cSt) 3 in³/min.
Maximum Valve Leakage at 110 SUS (24 cSt) (metric) 50 cc/min.
Response Time – Typical 25 ms
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 1 1/8 in.
Valve Hex Size (metric) 28,6 mm
Valve Installation Torque 45 – 50 lbf ft
Valve Installation Torque (metric) 61 – 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.63 lb.
Model Weight (metric) 0.29 kg.
Seal kit – Cartridge Viton: 990202006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment
O Handknob with Panel Mount
F Hex Head Screw with Locknut
J Capped Screw Adjustment
M Capped Screw Adjustment with Lockwire Holes

Adjustment Range

A 100 – 3000 psi (7 – 210 bar), 1000 psi (70 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 1000 psi (70 bar) Standard Setting
C 150 – 6000 psi (10,5 – 420 bar), 1000 psi (70 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 400 psi (28 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
W 150 – 4500 psi (10,5 – 315 bar), 1000 psi (70 bar) Standard Setting
N 60 – 800 psi (4 – 55 bar), 400 psi (28 bar) Standard Setting

Seal Material

N Buna-N
V Viton

Material/Coating

/AP Stainless Steel, Passivated
Cavity: T-2A
Nominal Capacity: 30 gpm (120 lpm)
Downloads
PDFSTP
Possible variants

SQFBCAN, SQFB-CAN, SQFBCAN/AP, SQFB-CAN/AP, SQFBCAV, SQFB-CAV, SQFBCAV/AP, SQFB-CAV/AP, SQFBCBN, SQFB-CBN, SQFBCBN/AP, SQFB-CBN/AP, SQFBCBV, SQFB-CBV, SQFBCBV/AP, SQFB-CBV/AP, SQFBCCN, SQFB-CCN, SQFBCCN/AP, SQFB-CCN/AP, SQFBCCV, SQFB-CCV, SQFBCCV/AP, SQFB-CCV/AP, SQFBCDN, SQFB-CDN, SQFBCDN/AP, SQFB-CDN/AP, SQFBCDV, SQFB-CDV, SQFBCDV/AP, SQFB-CDV/AP, SQFBCEN, SQFB-CEN, SQFBCEN/AP, SQFB-CEN/AP, SQFBCEV, SQFB-CEV, SQFBCEV/AP, SQFB-CEV/AP, SQFBCNN, SQFB-CNN, SQFBCNN/AP, SQFB-CNN/AP, SQFBCNV, SQFB-CNV, SQFBCNV/AP, SQFB-CNV/AP, SQFBCWN, SQFB-CWN, SQFBCWN/AP, SQFB-CWN/AP, SQFBCWV, SQFB-CWV, SQFBCWV/AP, SQFB-CWV/AP, SQFBFAN, SQFB-FAN, SQFBFAV, SQFB-FAV, SQFBFBN, SQFB-FBN, SQFBFBV, SQFB-FBV, SQFBFCN, SQFB-FCN, SQFBFCV, SQFB-FCV, SQFBFDN, SQFB-FDN, SQFBFDV, SQFB-FDV, SQFBFEN, SQFB-FEN, SQFBFEV, SQFB-FEV, SQFBFNN, SQFB-FNN, SQFBFNV, SQFB-FNV, SQFBFWN, SQFB-FWN, SQFBFWV, SQFB-FWV, SQFBJAN, SQFB-JAN, SQFBJAV, SQFB-JAV, SQFBJBN, SQFB-JBN, SQFBJBV, SQFB-JBV, SQFBJCN, SQFB-JCN, SQFBJCV, SQFB-JCV, SQFBJDN, SQFB-JDN, SQFBJDV, SQFB-JDV, SQFBJEN, SQFB-JEN, SQFBJEV, SQFB-JEV, SQFBJNN, SQFB-JNN, SQFBJNV, SQFB-JNV, SQFBJWN, SQFB-JWN, SQFBJWV, SQFB-JWV, SQFBKAN, SQFB-KAN, SQFBKAV, SQFB-KAV, SQFBKBN, SQFB-KBN, SQFBKBV, SQFB-KBV, SQFBKCN, SQFB-KCN, SQFBKCV, SQFB-KCV, SQFBKDN, SQFB-KDN, SQFBKDV, SQFB-KDV, SQFBKEN, SQFB-KEN, SQFBKEV, SQFB-KEV, SQFBKNN, SQFB-KNN, SQFBKNV, SQFB-KNV, SQFBKWN, SQFB-KWN, SQFBKWV, SQFB-KWV, SQFBLAN, SQFB-LAN, SQFBLAN/AP, SQFB-LAN/AP, SQFBLAV, SQFB-LAV, SQFBLAV/AP, SQFB-LAV/AP, SQFBLBN, SQFB-LBN, SQFBLBN/AP, SQFB-LBN/AP, SQFBLBV, SQFB-LBV, SQFBLBV/AP, SQFB-LBV/AP, SQFBLCN, SQFB-LCN, SQFBLCN/AP, SQFB-LCN/AP, SQFBLCV, SQFB-LCV, SQFBLCV/AP, SQFB-LCV/AP, SQFBLDN, SQFB-LDN, SQFBLDN/AP, SQFB-LDN/AP, SQFBLDV, SQFB-LDV, SQFBLDV/AP, SQFB-LDV/AP, SQFBLEN, SQFB-LEN, SQFBLEN/AP, SQFB-LEN/AP, SQFBLEV, SQFB-LEV, SQFBLEV/AP, SQFB-LEV/AP, SQFBLNN, SQFB-LNN, SQFBLNN/AP, SQFB-LNN/AP, SQFBLNV, SQFB-LNV, SQFBLNV/AP, SQFB-LNV/AP, SQFBLWN, SQFB-LWN, SQFBLWN/AP, SQFB-LWN/AP, SQFBLWV, SQFB-LWV, SQFBLWV/AP, SQFB-LWV/AP, SQFBMAN, SQFB-MAN, SQFBMAV, SQFB-MAV, SQFBMBN, SQFB-MBN, SQFBMBV, SQFB-MBV, SQFBMCN, SQFB-MCN, SQFBMCV, SQFB-MCV, SQFBMDN, SQFB-MDN, SQFBMDV, SQFB-MDV, SQFBMEN, SQFB-MEN, SQFBMEV, SQFB-MEV, SQFBMNN, SQFB-MNN, SQFBMNV, SQFB-MNV, SQFBMWN, SQFB-MWN, SQFBMWV, SQFB-MWV, SQFBOAN, SQFB-OAN, SQFBOAV, SQFB-OAV, SQFBOBN, SQFB-OBN, SQFBOBV, SQFB-OBV, SQFBOCN, SQFB-OCN, SQFBOCV, SQFB-OCV, SQFBODN, SQFB-ODN, SQFBODV, SQFB-ODV, SQFBOEN, SQFB-OEN, SQFBOEV, SQFB-OEV, SQFBONN, SQFB-ONN, SQFBONV, SQFB-ONV, SQFBOWN, SQFB-OWN, SQFBOWV, SQFB-OWV