Hydnet - the specialist in intelligent hydraulic systems
Contact
SXEA

Sequence valve from Sun Hydraulics

Description

Direct-acting sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

Read more ▼
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Suitable for use in load holding applications.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-2A
Series 2
Capacity 30 gpm
Capacity (metric) 120 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at 2 in³/min.
Factory Pressure Settings Established at (metric) 30 cc/min.
Maximum Valve Leakage at Reseat 10 drops/min.
Maximum Valve Leakage at Reseat (metric) 0,7 cc/min.
Response Time – Typical 2 ms
Adjustment – No. of CW Turns from Min. to Max. setting 4
Valve Hex Size 1 1/8 in.
Valve Hex Size (metric) 28,6 mm
Valve Installation Torque 45 – 50 lbf ft
Valve Installation Torque (metric) 61 – 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.80 lb.
Model Weight (metric) 0.36 kg.
Seal kit – Cartridge Viton: 990202006

Configuration Options

Control

C Tamper Resistant – Factory Set
L Standard Screw Adjustment
K Handknob

Adjustment Range

A 500 – 3000 psi (35 – 210 bar), 1000 psi (70 bar) Standard Setting
B 300 – 1500 psi (20 – 105 bar), 1000 psi (70 bar) Standard Setting
C 2000 – 6000 psi (140 – 420 bar), 2000 psi (140 bar) Standard Setting
D 200 – 800 psi (14 – 55 bar), 400 psi (28 bar) Standard Setting
E 100 – 400 psi (7 – 28 bar), 200 psi (14 bar) Standard Setting
W 800 – 4500 psi (55 – 315 bar), 1000 psi (70 bar) Standard Setting

Seal Material

N Buna-N
V Viton

Material/Coating

/AP Stainless Steel, Passivated
Cavity: T-2A
Nominal Capacity: 30 gpm (120 lpm)
Downloads
PDFSTP
Possible variants

SXEACAN, SXEA-CAN, SXEACAN/AP, SXEA-CAN/AP, SXEACAV, SXEA-CAV, SXEACAV/AP, SXEA-CAV/AP, SXEACBN, SXEA-CBN, SXEACBN/AP, SXEA-CBN/AP, SXEACBV, SXEA-CBV, SXEACBV/AP, SXEA-CBV/AP, SXEACCN, SXEA-CCN, SXEACCN/AP, SXEA-CCN/AP, SXEACCV, SXEA-CCV, SXEACCV/AP, SXEA-CCV/AP, SXEACDN, SXEA-CDN, SXEACDN/AP, SXEA-CDN/AP, SXEACDV, SXEA-CDV, SXEACDV/AP, SXEA-CDV/AP, SXEACEN, SXEA-CEN, SXEACEN/AP, SXEA-CEN/AP, SXEACEV, SXEA-CEV, SXEACEV/AP, SXEA-CEV/AP, SXEACWN, SXEA-CWN, SXEACWN/AP, SXEA-CWN/AP, SXEACWV, SXEA-CWV, SXEACWV/AP, SXEA-CWV/AP, SXEAKAN, SXEA-KAN, SXEAKAV, SXEA-KAV, SXEAKBN, SXEA-KBN, SXEAKBV, SXEA-KBV, SXEAKCN, SXEA-KCN, SXEAKCV, SXEA-KCV, SXEAKDN, SXEA-KDN, SXEAKDV, SXEA-KDV, SXEAKEN, SXEA-KEN, SXEAKEV, SXEA-KEV, SXEAKWN, SXEA-KWN, SXEAKWV, SXEA-KWV, SXEALAN, SXEA-LAN, SXEALAN/AP, SXEA-LAN/AP, SXEALAV, SXEA-LAV, SXEALAV/AP, SXEA-LAV/AP, SXEALBN, SXEA-LBN, SXEALBN/AP, SXEA-LBN/AP, SXEALBV, SXEA-LBV, SXEALBV/AP, SXEA-LBV/AP, SXEALCN, SXEA-LCN, SXEALCN/AP, SXEA-LCN/AP, SXEALCV, SXEA-LCV, SXEALCV/AP, SXEA-LCV/AP, SXEALDN, SXEA-LDN, SXEALDN/AP, SXEA-LDN/AP, SXEALDV, SXEA-LDV, SXEALDV/AP, SXEA-LDV/AP, SXEALEN, SXEA-LEN, SXEALEN/AP, SXEA-LEN/AP, SXEALEV, SXEA-LEV, SXEALEV/AP, SXEA-LEV/AP, SXEALWN, SXEA-LWN, SXEALWN/AP, SXEA-LWN/AP, SXEALWV, SXEA-LWV, SXEALWV/AP, SXEA-LWV/AP