Hydnet - the specialist in intelligent hydraulic systems
Contact
RSFS

Sequence valve from Sun Hydraulics

Description

Pilot-operated, balanced poppet sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence), up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in the return line.

Read more ▼
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Suitable for use in load holding applications.
  • Because the modulating occurs inside the cartridge these valves are immune to most of the problems associated with cavitation, namely noise and manifold erosion.
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-2A
Series 2
Capacity 30 gpm
Capacity (metric) 120 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at 4 gpm
Factory Pressure Settings Established at (metric) 15 L/min.
Maximum Valve Leakage at Reseat 10 drops/min.
Maximum Valve Leakage at Reseat (metric) 0,7 cc/min.
Response Time – Typical 10 ms
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 1 1/8 in.
Valve Hex Size (metric) 28,6 mm
Valve Installation Torque 45 – 50 lbf ft
Valve Installation Torque (metric) 61 – 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.65 lb.
Model Weight (metric) 0.29 kg.
Seal kit – Cartridge Viton: 990402006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment

Adjustment Range

A 100 – 3000 psi (7 – 210 bar), 1000 psi (70 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 1000 psi (70 bar) Standard Setting
C 150 – 6000 psi (10,5 – 420 bar), 1000 psi (70 bar) Standard Setting
N 60 – 800 psi (4 – 55 bar), 200 psi (14 bar) Standard Setting
Q 60 – 400 psi (4 – 28 bar), 200 psi (14 bar) Standard Setting
W 150 – 4500 psi (10,5 – 315 bar), 1000 psi (70 bar) Standard Setting

Seal Material

N Buna-N
V Viton

Material/Coating

/AP Stainless Steel, Passivated
Cavity: T-2A
Nominal Capacity: 30 gpm (120 lpm)
Downloads
PDFSTP
Possible variants

RSFS8BN, RSFS-8BN, RSFS8BV, RSFS-8BV, RSFS8WN, RSFS-8WN, RSFS8WV, RSFS-8WV, RSFSCAN, RSFS-CAN, RSFSCAN/AP, RSFS-CAN/AP, RSFSCAV, RSFS-CAV, RSFSCAV/AP, RSFS-CAV/AP, RSFSCBN, RSFS-CBN, RSFSCBN/AP, RSFS-CBN/AP, RSFSCBV, RSFS-CBV, RSFSCBV/AP, RSFS-CBV/AP, RSFSCCN, RSFS-CCN, RSFSCCN/AP, RSFS-CCN/AP, RSFSCCV, RSFS-CCV, RSFSCCV/AP, RSFS-CCV/AP, RSFSCNN, RSFS-CNN, RSFSCNN/AP, RSFS-CNN/AP, RSFSCNV, RSFS-CNV, RSFSCNV/AP, RSFS-CNV/AP, RSFSCQN, RSFS-CQN, RSFSCQN/AP, RSFS-CQN/AP, RSFSCQV, RSFS-CQV, RSFSCQV/AP, RSFS-CQV/AP, RSFSCWN, RSFS-CWN, RSFSCWN/AP, RSFS-CWN/AP, RSFSCWV, RSFS-CWV, RSFSCWV/AP, RSFS-CWV/AP, RSFSKAN, RSFS-KAN, RSFSKAV, RSFS-KAV, RSFSKBN, RSFS-KBN, RSFSKBV, RSFS-KBV, RSFSKCN, RSFS-KCN, RSFSKCV, RSFS-KCV, RSFSKNN, RSFS-KNN, RSFSKNV, RSFS-KNV, RSFSKQN, RSFS-KQN, RSFSKQV, RSFS-KQV, RSFSKWN, RSFS-KWN, RSFSKWV, RSFS-KWV, RSFSLAN, RSFS-LAN, RSFSLAN/AP, RSFS-LAN/AP, RSFSLAV, RSFS-LAV, RSFSLAV/AP, RSFS-LAV/AP, RSFSLBN, RSFS-LBN, RSFSLBN/AP, RSFS-LBN/AP, RSFSLBV, RSFS-LBV, RSFSLBV/AP, RSFS-LBV/AP, RSFSLCN, RSFS-LCN, RSFSLCN/AP, RSFS-LCN/AP, RSFSLCV, RSFS-LCV, RSFSLCV/AP, RSFS-LCV/AP, RSFSLNN, RSFS-LNN, RSFSLNN/AP, RSFS-LNN/AP, RSFSLNV, RSFS-LNV, RSFSLNV/AP, RSFS-LNV/AP, RSFSLQN, RSFS-LQN, RSFSLQN/AP, RSFS-LQN/AP, RSFSLQV, RSFS-LQV, RSFSLQV/AP, RSFS-LQV/AP, RSFSLWN, RSFS-LWN, RSFSLWN/AP, RSFS-LWN/AP, RSFSLWV, RSFS-LWV, RSFSLWV/AP, RSFS-LWV/AP