Description

Atmospherically referenced, direct-acting sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of this sequence valve controls the pressure at port 1 relative to the atmospheric vent.

Read more ▼
  • Suitable for use in load holding applications.
  • Atmospherically referenced valves should only be used where it is impossible have a drain connection. Over time, the atmospherically referenced valves may leak externally or allow moisture into the spring chamber.
  • Approximately 1 drop (0,07 cc) of fluid will pass into the vented spring chamber every 4000 cycles.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-13A
Series 1
Capacity 15 gpm
Capacity (metric) 60 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at 2 in³/min.
Factory Pressure Settings Established at (metric) 30 cc/min.
Maximum Valve Leakage at Reseat 10 drops/min.
Maximum Valve Leakage at Reseat (metric) 0,7 cc/min.
Response Time – Typical 2 ms
Adjustment – No. of CW Turns from Min. to Max. setting 4
Valve Hex Size 7/8 in.
Valve Hex Size (metric) 22,2 mm
Valve Installation Torque 30 – 35 lbf ft
Valve Installation Torque (metric) 41 – 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.45 lb.
Model Weight (metric) 0.21 kg.
Seal kit – Cartridge Viton: 990010006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment

Adjustment Range

A 500 – 3000 psi (35 – 210 bar), 1000 psi (70 bar) Standard Setting
B 300 – 1500 psi (20 – 105 bar), 1000 psi (70 bar) Standard Setting
C 2000 – 6000 psi (140 – 420 bar), 2000 psi (140 bar) Standard Setting
D 200 – 800 psi (14 – 55 bar), 400 psi (28 bar) Standard Setting
E 100 – 400 psi (7 – 28 bar), 200 psi (14 bar) Standard Setting
W 800 – 4500 psi (55 – 315 bar), 1000 psi (70 bar) Standard Setting

Seal Material

N Buna-N
V Viton
E EPDM

Material/Coating

/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
Cavity: T-13A
Nominal Capacity: 15 gpm (60 lpm )
Downloads
PDFSTP
Possible variants

SXCBCAN, SXCB-CAN, SXCBCAN/AP, SXCB-CAN/AP, SXCBCAN/LH, SXCB-CAN/LH, SXCBCAV, SXCB-CAV, SXCBCAV/AP, SXCB-CAV/AP, SXCBCAV/LH, SXCB-CAV/LH, SXCBCBN, SXCB-CBN, SXCBCBV, SXCB-CBV, SXCBCCN, SXCB-CCN, SXCBCCN/AP, SXCB-CCN/AP, SXCBCCV, SXCB-CCV, SXCBCCV/AP, SXCB-CCV/AP, SXCBCDN, SXCB-CDN, SXCBCDV, SXCB-CDV, SXCBCEN, SXCB-CEN, SXCBCEV, SXCB-CEV, SXCBCWE, SXCB-CWE, SXCBCWN, SXCB-CWN, SXCBCWN/AP, SXCB-CWN/AP, SXCBCWV, SXCB-CWV, SXCBCWV/AP, SXCB-CWV/AP, SXCBKAN, SXCB-KAN, SXCBKAV, SXCB-KAV, SXCBKBN, SXCB-KBN, SXCBKBV, SXCB-KBV, SXCBKCN, SXCB-KCN, SXCBKCV, SXCB-KCV, SXCBKDN, SXCB-KDN, SXCBKDV, SXCB-KDV, SXCBKEN, SXCB-KEN, SXCBKEV, SXCB-KEV, SXCBKWE, SXCB-KWE, SXCBKWN, SXCB-KWN, SXCBKWV, SXCB-KWV, SXCBLAN, SXCB-LAN, SXCBLAN/AP, SXCB-LAN/AP, SXCBLAN/LH, SXCB-LAN/LH, SXCBLAV, SXCB-LAV, SXCBLAV/AP, SXCB-LAV/AP, SXCBLAV/LH, SXCB-LAV/LH, SXCBLBN, SXCB-LBN, SXCBLBV, SXCB-LBV, SXCBLCN, SXCB-LCN, SXCBLCN/AP, SXCB-LCN/AP, SXCBLCV, SXCB-LCV, SXCBLCV/AP, SXCB-LCV/AP, SXCBLDN, SXCB-LDN, SXCBLDV, SXCB-LDV, SXCBLEN, SXCB-LEN, SXCBLEV, SXCB-LEV, SXCBLWE, SXCB-LWE, SXCBLWN, SXCB-LWN, SXCBLWN/AP, SXCB-LWN/AP, SXCBLWV, SXCB-LWV, SXCBLWV/AP, SXCB-LWV/AP