Relief valve from Sun Hydraulics
The bi-directional, direct-acting relief cartridge is a normally closed, pressure-limiting valve used to protect hydraulic components from pressure transients. When the pressure differential between ports 1 and 2 exceeds the valve setting, the valve starts to open, throttling flow to limit the pressure rise, regardless of the direction.
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-10A |
| Series | 1 |
| Capacity | 25 gpm |
| Capacity (metric) | 95 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Factory Pressure Settings Established at | 4 gpm |
| Factory Pressure Settings Established at (metric) | 15 L/min. |
| Maximum Valve Leakage at Reseat | 10 drops/min. |
| Maximum Valve Leakage at Reseat (metric) | 0,7 cc/min. |
| Response Time – Typical | 2 ms |
| Reseat | >85% of setting |
| Hysteresis | ≤ 3 % |
| Adjustment – No. of CW Turns from Min. to Max. setting | 5 |
| Valve Hex Size | 7/8 in. |
| Valve Hex Size (metric) | 22,2 mm |
| Valve Installation Torque | 30 – 35 lbf ft |
| Valve Installation Torque (metric) | 41 – 47 Nm |
| Model Weight | 0.37 lb. |
| Model Weight (metric) | 0.17 kg. |
| U.S. Patent # | 11,384,857 |
| Seal kit – Cartridge | Viton: 990310006 |
Control
| C | Tamper Resistant – Factory Set |
| L | Standard Screw Adjustment |
Adjustment Range
| A | 1200 – 3000 psi (85-210 bar), 1500 psi (105 bar) Standard Setting |
| W | 3000 – 5000 psi (210 – 350 bar), 4000 psi (280 bar) Standard Setting |
Seal Material
| N | Buna-N |
| V | Viton |