Pressure reducing valve from Sun Hydraulics
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-163A |
| Series | 0 |
| Capacity | 5 gpm |
| Capacity (metric) | 20 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Factory Pressure Settings Established at | blocked control port (dead headed) |
| Control Pilot Flow | 7 – 10 in³/min. |
| Control Pilot Flow (metric) | 0,11 – 0,16 L/min. |
| Adjustment – No. of CW Turns from Min. to Max. setting | 5 |
| Valve Hex Size | 3/4 in. |
| Valve Hex Size (metric) | 19,1 mm |
| Valve Installation Torque | 20 – 25 lbf ft |
| Valve Installation Torque (metric) | 27 – 33 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in. |
| Adjustment Screw Internal Hex Size (metric) | 4 mm |
| Locknut Hex Size | 1/2 in. |
| Locknut Hex Size (metric) | 12,7 mm |
| Locknut Torque | 80 – 90 lbf in. |
| Locknut Torque (metric) | 9 – 10 Nm |
| Model Weight | 0.25 lb. |
| Model Weight (metric) | 0.11 kg. |
| Seal kit – Cartridge | Viton: 990163006 |
Control
| L ★ | Standard Screw Adjustment |
| C | Tamper Resistant – Factory Set |
| K | Handknob |
| W | Hex Wrench Adjustment |
Adjustment Range
| A ★ | 75 – 3000 psi (5 – 210 bar), 200 psi (14 bar) Standard Setting |
| W ★ | 75 – 4500 psi (5 – 315 bar), 200 psi (14 bar) Standard Setting |
| B | 75 – 1500 psi (5 – 105 bar), 200 psi (14 bar) Standard Setting |
| N | 75 – 800 psi (5 – 55 bar), 200 psi (14 bar) Standard Setting |
| Q | 75 – 400 psi (5 – 28 bar), 200 psi (14 bar) Standard Setting |
Seal Material
| N ★ | Buna-N |
| V | Viton |
| E | EPDM |
Material/Coating
| /AP | Stainless Steel, Passivated |
| /LH | Mild Steel, Zinc-Nickel |