Hydnet - the specialist in intelligent hydraulic systems
Contact
PVHA

Pressure reducing/relieving valve from Sun Hydraulics

Description

Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.

Read more ▼
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pressure at port 4 should not exceed 5000 psi (350 bar).
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-23A
Series 3
Capacity 40 gpm
Capacity (metric) 160 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at blocked control port (dead headed)
Control Pilot Flow 15 – 20 in³/min.
Control Pilot Flow (metric) 0,25 – 0,33 L/min.
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 1 1/4 in.
Valve Hex Size (metric) 31,8 mm
Valve Installation Torque 150 – 160 lbf ft
Valve Installation Torque (metric) 203 – 217 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 1.55 lb.
Model Weight (metric) 0.70 kg.
Seal kit – Cartridge Viton: 990023006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment

Adjustment Range

A 100 – 3000 psi (7 – 210 bar), 200 psi (14 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 200 psi (14 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 200 psi (14 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
W 150 – 4500 psi (10,5 – 315 bar), 200 psi (14 bar) Standard Setting
H 30 – 3000 psi (2 – 210 bar), 200 psi (14 bar) Standard Setting
J 25 – 1500 psi (1,7 – 105 bar), 200 psi (14 bar) Standard Setting

Seal Material

N Buna-N
V Viton
E EPDM

Material/Coating

/AP Stainless Steel, Passivated
Cavity: T-23A
Nominal Capacity: 40 gpm (160 lpm)
Downloads
PDFSTP
Possible variants

PVHA8DE, PVHA-8DE, PVHA8DN, PVHA-8DN, PVHA8DV, PVHA-8DV, PVHA8WE, PVHA-8WE, PVHA8WN, PVHA-8WN, PVHA8WV, PVHA-8WV, PVHACAE, PVHA-CAE, PVHACAN, PVHA-CAN, PVHACAN/AP, PVHA-CAN/AP, PVHACAV, PVHA-CAV, PVHACAV/AP, PVHA-CAV/AP, PVHACBE, PVHA-CBE, PVHACBN, PVHA-CBN, PVHACBN/AP, PVHA-CBN/AP, PVHACBV, PVHA-CBV, PVHACBV/AP, PVHA-CBV/AP, PVHACDE, PVHA-CDE, PVHACDN, PVHA-CDN, PVHACDN/AP, PVHA-CDN/AP, PVHACDV, PVHA-CDV, PVHACDV/AP, PVHA-CDV/AP, PVHACEE, PVHA-CEE, PVHACEN, PVHA-CEN, PVHACEN/AP, PVHA-CEN/AP, PVHACEV, PVHA-CEV, PVHACEV/AP, PVHA-CEV/AP, PVHACHE, PVHA-CHE, PVHACHN, PVHA-CHN, PVHACHN/AP, PVHA-CHN/AP, PVHACHV, PVHA-CHV, PVHACHV/AP, PVHA-CHV/AP, PVHACJE, PVHA-CJE, PVHACJN, PVHA-CJN, PVHACJN/AP, PVHA-CJN/AP, PVHACJV, PVHA-CJV, PVHACJV/AP, PVHA-CJV/AP, PVHACWE, PVHA-CWE, PVHACWN, PVHA-CWN, PVHACWN/AP, PVHA-CWN/AP, PVHACWV, PVHA-CWV, PVHACWV/AP, PVHA-CWV/AP, PVHAKAE, PVHA-KAE, PVHAKAN, PVHA-KAN, PVHAKAV, PVHA-KAV, PVHAKBE, PVHA-KBE, PVHAKBN, PVHA-KBN, PVHAKBV, PVHA-KBV, PVHAKDE, PVHA-KDE, PVHAKDN, PVHA-KDN, PVHAKDV, PVHA-KDV, PVHAKEE, PVHA-KEE, PVHAKEN, PVHA-KEN, PVHAKEV, PVHA-KEV, PVHAKHE, PVHA-KHE, PVHAKHN, PVHA-KHN, PVHAKHV, PVHA-KHV, PVHAKJE, PVHA-KJE, PVHAKJN, PVHA-KJN, PVHAKJV, PVHA-KJV, PVHAKWE, PVHA-KWE, PVHAKWN, PVHA-KWN, PVHAKWV, PVHA-KWV, PVHALAE, PVHA-LAE, PVHALAN, PVHA-LAN, PVHALAN/AP, PVHA-LAN/AP, PVHALAV, PVHA-LAV, PVHALAV/AP, PVHA-LAV/AP, PVHALBE, PVHA-LBE, PVHALBN, PVHA-LBN, PVHALBN/AP, PVHA-LBN/AP, PVHALBV, PVHA-LBV, PVHALBV/AP, PVHA-LBV/AP, PVHALDE, PVHA-LDE, PVHALDN, PVHA-LDN, PVHALDN/AP, PVHA-LDN/AP, PVHALDV, PVHA-LDV, PVHALDV/AP, PVHA-LDV/AP, PVHALEE, PVHA-LEE, PVHALEN, PVHA-LEN, PVHALEN/AP, PVHA-LEN/AP, PVHALEV, PVHA-LEV, PVHALEV/AP, PVHA-LEV/AP, PVHALHE, PVHA-LHE, PVHALHN, PVHA-LHN, PVHALHN/AP, PVHA-LHN/AP, PVHALHV, PVHA-LHV, PVHALHV/AP, PVHA-LHV/AP, PVHALJE, PVHA-LJE, PVHALJN, PVHA-LJN, PVHALJN/AP, PVHA-LJN/AP, PVHALJV, PVHA-LJV, PVHALJV/AP, PVHA-LJV/AP, PVHALWE, PVHA-LWE, PVHALWN, PVHA-LWN, PVHALWN/AP, PVHA-LWN/AP, PVHALWV, PVHA-LWV, PVHALWV/AP, PVHA-LWV/AP