Hydnet - the specialist in intelligent hydraulic systems
Contact
PVFA

Pressure reducing/relieving valve from Sun Hydraulics

Description

Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.

Read more ▼
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pressure at port 4 should not exceed 5000 psi (350 bar).
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-22A
Series 2
Capacity 20 gpm
Capacity (metric) 80 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at blocked control port (dead headed)
Control Pilot Flow 10 – 15 in³/min.
Control Pilot Flow (metric) 0,16 – 0,25 L/min.
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 1 1/8 in.
Valve Hex Size (metric) 28,6 mm
Valve Installation Torque 45 – 50 lbf ft
Valve Installation Torque (metric) 61 – 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.74 lb.
Model Weight (metric) 0.34 kg.
Seal kit – Cartridge Viton: 990022006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment
W Hex Wrench Adjustment
Y Tri-Grip Handknob

Adjustment Range

A 100 – 3000 psi (7 – 210 bar), 200 psi (14 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 200 psi (14 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 200 psi (14 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
W 150 – 4500 psi (10,5 – 315 bar), 200 psi (14 bar) Standard Setting
H 30 – 3000 psi (2 – 210 bar), 200 psi (14 bar) Standard Setting

Seal Material

N Buna-N
V Viton
E EPDM

Material/Coating

/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
Cavity: T-22A
Nominal Capacity: 80 lpm (20 gpm)
Downloads
PDFSTP
Possible variants

PVFA8DE, PVFA-8DE, PVFA8DN, PVFA-8DN, PVFA8DV, PVFA-8DV, PVFA8WE, PVFA-8WE, PVFA8WN, PVFA-8WN, PVFA8WV, PVFA-8WV, PVFACAE, PVFA-CAE, PVFACAN, PVFA-CAN, PVFACAN/AP, PVFA-CAN/AP, PVFACAN/LH, PVFA-CAN/LH, PVFACAV, PVFA-CAV, PVFACAV/AP, PVFA-CAV/AP, PVFACAV/LH, PVFA-CAV/LH, PVFACBE, PVFA-CBE, PVFACBN, PVFA-CBN, PVFACBN/AP, PVFA-CBN/AP, PVFACBN/LH, PVFA-CBN/LH, PVFACBV, PVFA-CBV, PVFACBV/AP, PVFA-CBV/AP, PVFACBV/LH, PVFA-CBV/LH, PVFACDE, PVFA-CDE, PVFACDN, PVFA-CDN, PVFACDN/AP, PVFA-CDN/AP, PVFACDN/LH, PVFA-CDN/LH, PVFACDV, PVFA-CDV, PVFACDV/AP, PVFA-CDV/AP, PVFACDV/LH, PVFA-CDV/LH, PVFACEE, PVFA-CEE, PVFACEN, PVFA-CEN, PVFACEN/AP, PVFA-CEN/AP, PVFACEN/LH, PVFA-CEN/LH, PVFACEV, PVFA-CEV, PVFACEV/AP, PVFA-CEV/AP, PVFACEV/LH, PVFA-CEV/LH, PVFACHE, PVFA-CHE, PVFACHN, PVFA-CHN, PVFACHN/AP, PVFA-CHN/AP, PVFACHN/LH, PVFA-CHN/LH, PVFACHV, PVFA-CHV, PVFACHV/AP, PVFA-CHV/AP, PVFACHV/LH, PVFA-CHV/LH, PVFACWE, PVFA-CWE, PVFACWN, PVFA-CWN, PVFACWN/AP, PVFA-CWN/AP, PVFACWN/LH, PVFA-CWN/LH, PVFACWV, PVFA-CWV, PVFACWV/AP, PVFA-CWV/AP, PVFACWV/LH, PVFA-CWV/LH, PVFAKAE, PVFA-KAE, PVFAKAN, PVFA-KAN, PVFAKAV, PVFA-KAV, PVFAKBE, PVFA-KBE, PVFAKBN, PVFA-KBN, PVFAKBV, PVFA-KBV, PVFAKDE, PVFA-KDE, PVFAKDN, PVFA-KDN, PVFAKDV, PVFA-KDV, PVFAKEE, PVFA-KEE, PVFAKEN, PVFA-KEN, PVFAKEV, PVFA-KEV, PVFAKHE, PVFA-KHE, PVFAKHN, PVFA-KHN, PVFAKHV, PVFA-KHV, PVFAKWE, PVFA-KWE, PVFAKWN, PVFA-KWN, PVFAKWV, PVFA-KWV, PVFALAE, PVFA-LAE, PVFALAN, PVFA-LAN, PVFALAN/AP, PVFA-LAN/AP, PVFALAN/LH, PVFA-LAN/LH, PVFALAV, PVFA-LAV, PVFALAV/AP, PVFA-LAV/AP, PVFALAV/LH, PVFA-LAV/LH, PVFALBE, PVFA-LBE, PVFALBN, PVFA-LBN, PVFALBN/AP, PVFA-LBN/AP, PVFALBN/LH, PVFA-LBN/LH, PVFALBV, PVFA-LBV, PVFALBV/AP, PVFA-LBV/AP, PVFALBV/LH, PVFA-LBV/LH, PVFALDE, PVFA-LDE, PVFALDN, PVFA-LDN, PVFALDN/AP, PVFA-LDN/AP, PVFALDN/LH, PVFA-LDN/LH, PVFALDV, PVFA-LDV, PVFALDV/AP, PVFA-LDV/AP, PVFALDV/LH, PVFA-LDV/LH, PVFALEE, PVFA-LEE, PVFALEN, PVFA-LEN, PVFALEN/AP, PVFA-LEN/AP, PVFALEN/LH, PVFA-LEN/LH, PVFALEV, PVFA-LEV, PVFALEV/AP, PVFA-LEV/AP, PVFALEV/LH, PVFA-LEV/LH, PVFALHE, PVFA-LHE, PVFALHN, PVFA-LHN, PVFALHN/AP, PVFA-LHN/AP, PVFALHN/LH, PVFA-LHN/LH, PVFALHV, PVFA-LHV, PVFALHV/AP, PVFA-LHV/AP, PVFALHV/LH, PVFA-LHV/LH, PVFALWE, PVFA-LWE, PVFALWN, PVFA-LWN, PVFALWN/AP, PVFA-LWN/AP, PVFALWN/LH, PVFA-LWN/LH, PVFALWV, PVFA-LWV, PVFALWV/AP, PVFA-LWV/AP, PVFALWV/LH, PVFA-LWV/LH, PVFAWAE, PVFA-WAE, PVFAWAN, PVFA-WAN, PVFAWAV, PVFA-WAV, PVFAWBE, PVFA-WBE, PVFAWBN, PVFA-WBN, PVFAWBV, PVFA-WBV, PVFAWDE, PVFA-WDE, PVFAWDN, PVFA-WDN, PVFAWDV, PVFA-WDV, PVFAWEE, PVFA-WEE, PVFAWEN, PVFA-WEN, PVFAWEV, PVFA-WEV, PVFAWHE, PVFA-WHE, PVFAWHN, PVFA-WHN, PVFAWHV, PVFA-WHV, PVFAWWE, PVFA-WWE, PVFAWWN, PVFA-WWN, PVFAWWV, PVFA-WWV, PVFAYAE, PVFA-YAE, PVFAYAN, PVFA-YAN, PVFAYAV, PVFA-YAV, PVFAYBE, PVFA-YBE, PVFAYBN, PVFA-YBN, PVFAYBV, PVFA-YBV, PVFAYDE, PVFA-YDE, PVFAYDN, PVFA-YDN, PVFAYDV, PVFA-YDV, PVFAYEE, PVFA-YEE, PVFAYEN, PVFA-YEN, PVFAYEV, PVFA-YEV, PVFAYHE, PVFA-YHE, PVFAYHN, PVFA-YHN, PVFAYHV, PVFA-YHV, PVFAYWE, PVFA-YWE, PVFAYWN, PVFA-YWN, PVFAYWV, PVFA-YWV