Pressure reducing/relieving valve from Sun Hydraulics

Description

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

Read more ▼
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-163A
Series 0
Capacity 5 gpm
Capacity (metric) 20 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at 0.25 gpm
Maximum Valve Leakage at 110 SUS (24 cSt) 2 in³/min.
Maximum Valve Leakage at 110 SUS (24 cSt) (metric) 30 cc/min.
Adjustment – No. of CW Turns from Min. to Max. setting 7
Valve Hex Size 3/4 in.
Valve Hex Size (metric) 19,1 mm
Valve Installation Torque 20 – 25 lbf ft
Valve Installation Torque (metric) 27 – 33 Nm
Locknut Hex Size 1/2 in.
Locknut Hex Size (metric) 12,7 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.30 lb.
Model Weight (metric) 0.14 kg.
Seal kit – Cartridge Viton: 990163006

Configuration Options

Control

L ★ Standard Screw Adjustment
C Tamper Resistant – Factory Set
K Handknob

Adjustment Range

A 500 – 3000 psi (35 – 210 bar), 700 psi (50 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 200 psi (14 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 200 psi (14 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
S 25 – 200 psi (1,7 – 14 bar), 100 psi (7 bar) Standard Setting
W 750 – 4500 psi (50 – 315 bar), 1000 psi (70 bar) Standard Setting

Seal Material

N Buna-N
V Viton
E EPDM

Material/Coating

/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
Cavity: T-163A
Nominal Capacity: 20 lpm (5 gpm)
Downloads
PDF
Possible variants

PRBBCAE, PRBB-CAE, PRBBCAN, PRBB-CAN, PRBBCAN/AP, PRBB-CAN/AP, PRBBCAN/LH, PRBB-CAN/LH, PRBBCAV, PRBB-CAV, PRBBCAV/AP, PRBB-CAV/AP, PRBBCAV/LH, PRBB-CAV/LH, PRBBCBE, PRBB-CBE, PRBBCBN, PRBB-CBN, PRBBCBN/AP, PRBB-CBN/AP, PRBBCBN/LH, PRBB-CBN/LH, PRBBCBV, PRBB-CBV, PRBBCBV/AP, PRBB-CBV/AP, PRBBCBV/LH, PRBB-CBV/LH, PRBBCDE, PRBB-CDE, PRBBCDN, PRBB-CDN, PRBBCDN/AP, PRBB-CDN/AP, PRBBCDN/LH, PRBB-CDN/LH, PRBBCDV, PRBB-CDV, PRBBCDV/AP, PRBB-CDV/AP, PRBBCDV/LH, PRBB-CDV/LH, PRBBCEE, PRBB-CEE, PRBBCEN, PRBB-CEN, PRBBCEN/AP, PRBB-CEN/AP, PRBBCEN/LH, PRBB-CEN/LH, PRBBCEV, PRBB-CEV, PRBBCEV/AP, PRBB-CEV/AP, PRBBCEV/LH, PRBB-CEV/LH, PRBBCSE, PRBB-CSE, PRBBCSN, PRBB-CSN, PRBBCSN/AP, PRBB-CSN/AP, PRBBCSN/LH, PRBB-CSN/LH, PRBBCSV, PRBB-CSV, PRBBCSV/AP, PRBB-CSV/AP, PRBBCSV/LH, PRBB-CSV/LH, PRBBCWE, PRBB-CWE, PRBBCWN, PRBB-CWN, PRBBCWN/AP, PRBB-CWN/AP, PRBBCWN/LH, PRBB-CWN/LH, PRBBCWV, PRBB-CWV, PRBBCWV/AP, PRBB-CWV/AP, PRBBCWV/LH, PRBB-CWV/LH, PRBBKAE, PRBB-KAE, PRBBKAN, PRBB-KAN, PRBBKAV, PRBB-KAV, PRBBKBE, PRBB-KBE, PRBBKBN, PRBB-KBN, PRBBKBV, PRBB-KBV, PRBBKDE, PRBB-KDE, PRBBKDN, PRBB-KDN, PRBBKDV, PRBB-KDV, PRBBKEE, PRBB-KEE, PRBBKEN, PRBB-KEN, PRBBKEV, PRBB-KEV, PRBBKSE, PRBB-KSE, PRBBKSN, PRBB-KSN, PRBBKSV, PRBB-KSV, PRBBKWE, PRBB-KWE, PRBBKWN, PRBB-KWN, PRBBKWV, PRBB-KWV, PRBBLAE, PRBB-LAE, PRBBLAN, PRBB-LAN, PRBBLAN/AP, PRBB-LAN/AP, PRBBLAN/LH, PRBB-LAN/LH, PRBBLAV, PRBB-LAV, PRBBLAV/AP, PRBB-LAV/AP, PRBBLAV/LH, PRBB-LAV/LH, PRBBLBE, PRBB-LBE, PRBBLBN, PRBB-LBN, PRBBLBN/AP, PRBB-LBN/AP, PRBBLBN/LH, PRBB-LBN/LH, PRBBLBV, PRBB-LBV, PRBBLBV/AP, PRBB-LBV/AP, PRBBLBV/LH, PRBB-LBV/LH, PRBBLDE, PRBB-LDE, PRBBLDN, PRBB-LDN, PRBBLDN/AP, PRBB-LDN/AP, PRBBLDN/LH, PRBB-LDN/LH, PRBBLDV, PRBB-LDV, PRBBLDV/AP, PRBB-LDV/AP, PRBBLDV/LH, PRBB-LDV/LH, PRBBLEE, PRBB-LEE, PRBBLEN, PRBB-LEN, PRBBLEN/AP, PRBB-LEN/AP, PRBBLEN/LH, PRBB-LEN/LH, PRBBLEV, PRBB-LEV, PRBBLEV/AP, PRBB-LEV/AP, PRBBLEV/LH, PRBB-LEV/LH, PRBBLSE, PRBB-LSE, PRBBLSN, PRBB-LSN, PRBBLSN/AP, PRBB-LSN/AP, PRBBLSN/LH, PRBB-LSN/LH, PRBBLSV, PRBB-LSV, PRBBLSV/AP, PRBB-LSV/AP, PRBBLSV/LH, PRBB-LSV/LH, PRBBLWE, PRBB-LWE, PRBBLWN, PRBB-LWN, PRBBLWN/AP, PRBB-LWN/AP, PRBBLWN/LH, PRBB-LWN/LH, PRBBLWV, PRBB-LWV, PRBBLWV/AP, PRBB-LWV/AP, PRBBLWV/LH, PRBB-LWV/LH