Hydnet - the specialist in intelligent hydraulic systems
Contact
PPDF

Pressure reducing/relieving valve from Sun Hydraulics

Description

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

Read more ▼
  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-11A
Series 1
Capacity 10 gpm
Capacity (metric) 40 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at blocked control port (dead headed)
Control Pilot Flow 7 – 10 in³/min.
Control Pilot Flow (metric) 0,11 – 0,16 L/min.
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 7/8 in.
Valve Hex Size (metric) 22,2 mm
Valve Installation Torque 30 – 35 lbf ft
Valve Installation Torque (metric) 41 – 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.39 lb.
Model Weight (metric) 0.17 kg.
Seal kit – Cartridge Viton: 990011006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment
Y Tri-Grip Handknob
O Handknob with Panel Mount
Q Capped and Lockwired

Adjustment Range

A 100 – 3000 psi (7 – 210 bar), 200 psi (14 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 200 psi (14 bar) Standard Setting
N 60 – 800 psi (4 – 55 bar), 200 psi (14 bar) Standard Setting
Q 60 – 400 psi (4 – 28 bar), 200 psi (14 bar) Standard Setting
W 150 – 4500 psi (10,5 – 315 bar), 200 psi (14 bar) Standard Setting
C 150 – 6000 psi (10,5 – 420 bar), 200 psi (14 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 200 psi (14 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
H 30 – 3000 psi (2 – 210 bar), 200 psi (14 bar) Standard Setting
J 25 – 1500 psi (1,7 – 105 bar), 200 psi (14 bar) Standard Setting
K 75 – 1500 psi (5 – 105 bar), 200 psi (14 bar) Standard Setting
O 150 – 400 psi (10 – 28 bar), 200 psi (14 bar) Standard Setting
P 40 – 400 psi (2,8 – 28 bar), 200 psi (14 bar) Standard Setting

Seal Material

N Buna-N
V Viton
Cavity: T-11A
Nominal Capacity: 40 lpm (10 gpm)
Downloads
PDFSTP
Possible variants

PPDF8DN, PPDF-8DN, PPDF8DV, PPDF-8DV, PPDF8WN, PPDF-8WN, PPDF8WV, PPDF-8WV, PPDFCAN, PPDF-CAN, PPDFCAV, PPDF-CAV, PPDFCBN, PPDF-CBN, PPDFCBV, PPDF-CBV, PPDFCCN, PPDF-CCN, PPDFCCV, PPDF-CCV, PPDFCDN, PPDF-CDN, PPDFCDV, PPDF-CDV, PPDFCEN, PPDF-CEN, PPDFCEV, PPDF-CEV, PPDFCHN, PPDF-CHN, PPDFCHV, PPDF-CHV, PPDFCJN, PPDF-CJN, PPDFCJV, PPDF-CJV, PPDFCKN, PPDF-CKN, PPDFCKV, PPDF-CKV, PPDFCNN, PPDF-CNN, PPDFCNV, PPDF-CNV, PPDFCON, PPDF-CON, PPDFCOV, PPDF-COV, PPDFCPN, PPDF-CPN, PPDFCPV, PPDF-CPV, PPDFCQN, PPDF-CQN, PPDFCQV, PPDF-CQV, PPDFCWN, PPDF-CWN, PPDFCWV, PPDF-CWV, PPDFKAN, PPDF-KAN, PPDFKAV, PPDF-KAV, PPDFKBN, PPDF-KBN, PPDFKBV, PPDF-KBV, PPDFKCN, PPDF-KCN, PPDFKCV, PPDF-KCV, PPDFKDN, PPDF-KDN, PPDFKDV, PPDF-KDV, PPDFKEN, PPDF-KEN, PPDFKEV, PPDF-KEV, PPDFKHN, PPDF-KHN, PPDFKHV, PPDF-KHV, PPDFKJN, PPDF-KJN, PPDFKJV, PPDF-KJV, PPDFKKN, PPDF-KKN, PPDFKKV, PPDF-KKV, PPDFKNN, PPDF-KNN, PPDFKNV, PPDF-KNV, PPDFKON, PPDF-KON, PPDFKOV, PPDF-KOV, PPDFKPN, PPDF-KPN, PPDFKPV, PPDF-KPV, PPDFKQN, PPDF-KQN, PPDFKQV, PPDF-KQV, PPDFKWN, PPDF-KWN, PPDFKWV, PPDF-KWV, PPDFLAN, PPDF-LAN, PPDFLAV, PPDF-LAV, PPDFLBN, PPDF-LBN, PPDFLBV, PPDF-LBV, PPDFLCN, PPDF-LCN, PPDFLCV, PPDF-LCV, PPDFLDN, PPDF-LDN, PPDFLDV, PPDF-LDV, PPDFLEN, PPDF-LEN, PPDFLEV, PPDF-LEV, PPDFLHN, PPDF-LHN, PPDFLHV, PPDF-LHV, PPDFLJN, PPDF-LJN, PPDFLJV, PPDF-LJV, PPDFLKN, PPDF-LKN, PPDFLKV, PPDF-LKV, PPDFLNN, PPDF-LNN, PPDFLNV, PPDF-LNV, PPDFLON, PPDF-LON, PPDFLOV, PPDF-LOV, PPDFLPN, PPDF-LPN, PPDFLPV, PPDF-LPV, PPDFLQN, PPDF-LQN, PPDFLQV, PPDF-LQV, PPDFLWN, PPDF-LWN, PPDFLWV, PPDF-LWV, PPDFOAN, PPDF-OAN, PPDFOAV, PPDF-OAV, PPDFOBN, PPDF-OBN, PPDFOBV, PPDF-OBV, PPDFOCN, PPDF-OCN, PPDFOCV, PPDF-OCV, PPDFODN, PPDF-ODN, PPDFODV, PPDF-ODV, PPDFOEN, PPDF-OEN, PPDFOEV, PPDF-OEV, PPDFOHN, PPDF-OHN, PPDFOHV, PPDF-OHV, PPDFOJN, PPDF-OJN, PPDFOJV, PPDF-OJV, PPDFOKN, PPDF-OKN, PPDFOKV, PPDF-OKV, PPDFONN, PPDF-ONN, PPDFONV, PPDF-ONV, PPDFOON, PPDF-OON, PPDFOOV, PPDF-OOV, PPDFOPN, PPDF-OPN, PPDFOPV, PPDF-OPV, PPDFOQN, PPDF-OQN, PPDFOQV, PPDF-OQV, PPDFOWN, PPDF-OWN, PPDFOWV, PPDF-OWV, PPDFQAN, PPDF-QAN, PPDFQAV, PPDF-QAV, PPDFQBN, PPDF-QBN, PPDFQBV, PPDF-QBV, PPDFQCN, PPDF-QCN, PPDFQCV, PPDF-QCV, PPDFQDN, PPDF-QDN, PPDFQDV, PPDF-QDV, PPDFQEN, PPDF-QEN, PPDFQEV, PPDF-QEV, PPDFQHN, PPDF-QHN, PPDFQHV, PPDF-QHV, PPDFQJN, PPDF-QJN, PPDFQJV, PPDF-QJV, PPDFQKN, PPDF-QKN, PPDFQKV, PPDF-QKV, PPDFQNN, PPDF-QNN, PPDFQNV, PPDF-QNV, PPDFQON, PPDF-QON, PPDFQOV, PPDF-QOV, PPDFQPN, PPDF-QPN, PPDFQPV, PPDF-QPV, PPDFQQN, PPDF-QQN, PPDFQQV, PPDF-QQV, PPDFQWN, PPDF-QWN, PPDFQWV, PPDF-QWV, PPDFYAN, PPDF-YAN, PPDFYAV, PPDF-YAV, PPDFYBN, PPDF-YBN, PPDFYBV, PPDF-YBV, PPDFYCN, PPDF-YCN, PPDFYCV, PPDF-YCV, PPDFYDN, PPDF-YDN, PPDFYDV, PPDF-YDV, PPDFYEN, PPDF-YEN, PPDFYEV, PPDF-YEV, PPDFYHN, PPDF-YHN, PPDFYHV, PPDF-YHV, PPDFYJN, PPDF-YJN, PPDFYJV, PPDF-YJV, PPDFYKN, PPDF-YKN, PPDFYKV, PPDF-YKV, PPDFYNN, PPDF-YNN, PPDFYNV, PPDF-YNV, PPDFYON, PPDF-YON, PPDFYOV, PPDF-YOV, PPDFYPN, PPDF-YPN, PPDFYPV, PPDF-YPV, PPDFYQN, PPDF-YQN, PPDFYQV, PPDF-YQV, PPDFYWN, PPDF-YWN, PPDFYWV, PPDF-YWV