Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

Read more ▼
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-24A
Series 4
Capacity 80 gpm
Capacity (metric) 320 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at blocked control port (dead headed)
Control Pilot Flow 15 – 20 in³/min.
Control Pilot Flow (metric) 0,25 – 0,33 L/min.
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 1 5/8 in.
Valve Hex Size (metric) 41,3 mm
Valve Installation Torque 350 – 375 lbf ft
Valve Installation Torque (metric) 474 – 508 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 3.53 lb.
Model Weight (metric) 1.60 kg.
Seal kit – Cartridge Viton: 990024006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment

Adjustment Range

A 100 – 3000 psi (7 – 210 bar), 200 psi (14 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 200 psi (14 bar) Standard Setting
C 150 – 6000 psi (10,5 – 420 bar), 200 psi (14 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 200 psi (14 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
H 30 – 3000 psi (2 – 210 bar), 200 psi (14 bar) Standard Setting
J 25 – 1500 psi (1,7 – 105 bar), 200 psi (14 bar) Standard Setting
W 100 – 4500 psi (7 – 315 bar), 200 psi (14 bar) Standard Setting

Seal Material

N Buna-N
V Viton

Material/Coating

/AP Stainless Steel, Passivated
Cavity: T-24A
Nominal Capacity: 320 lpm (80 gpm)
Downloads
PDFSTP
Possible variants

PVJDCAN, PVJD-CAN, PVJDCAN/AP, PVJD-CAN/AP, PVJDCAV, PVJD-CAV, PVJDCAV/AP, PVJD-CAV/AP, PVJDCBN, PVJD-CBN, PVJDCBN/AP, PVJD-CBN/AP, PVJDCBV, PVJD-CBV, PVJDCBV/AP, PVJD-CBV/AP, PVJDCCN, PVJD-CCN, PVJDCCN/AP, PVJD-CCN/AP, PVJDCCV, PVJD-CCV, PVJDCCV/AP, PVJD-CCV/AP, PVJDCDN, PVJD-CDN, PVJDCDN/AP, PVJD-CDN/AP, PVJDCDV, PVJD-CDV, PVJDCDV/AP, PVJD-CDV/AP, PVJDCEN, PVJD-CEN, PVJDCEN/AP, PVJD-CEN/AP, PVJDCEV, PVJD-CEV, PVJDCEV/AP, PVJD-CEV/AP, PVJDCHN, PVJD-CHN, PVJDCHN/AP, PVJD-CHN/AP, PVJDCHV, PVJD-CHV, PVJDCHV/AP, PVJD-CHV/AP, PVJDCJN, PVJD-CJN, PVJDCJN/AP, PVJD-CJN/AP, PVJDCJV, PVJD-CJV, PVJDCJV/AP, PVJD-CJV/AP, PVJDCWN, PVJD-CWN, PVJDCWN/AP, PVJD-CWN/AP, PVJDCWV, PVJD-CWV, PVJDCWV/AP, PVJD-CWV/AP, PVJDKAN, PVJD-KAN, PVJDKAV, PVJD-KAV, PVJDKBN, PVJD-KBN, PVJDKBV, PVJD-KBV, PVJDKCN, PVJD-KCN, PVJDKCV, PVJD-KCV, PVJDKDN, PVJD-KDN, PVJDKDV, PVJD-KDV, PVJDKEN, PVJD-KEN, PVJDKEV, PVJD-KEV, PVJDKHN, PVJD-KHN, PVJDKHV, PVJD-KHV, PVJDKJN, PVJD-KJN, PVJDKJV, PVJD-KJV, PVJDKWN, PVJD-KWN, PVJDKWV, PVJD-KWV, PVJDLAN, PVJD-LAN, PVJDLAN/AP, PVJD-LAN/AP, PVJDLAV, PVJD-LAV, PVJDLAV/AP, PVJD-LAV/AP, PVJDLBN, PVJD-LBN, PVJDLBN/AP, PVJD-LBN/AP, PVJDLBV, PVJD-LBV, PVJDLBV/AP, PVJD-LBV/AP, PVJDLCN, PVJD-LCN, PVJDLCN/AP, PVJD-LCN/AP, PVJDLCV, PVJD-LCV, PVJDLCV/AP, PVJD-LCV/AP, PVJDLDN, PVJD-LDN, PVJDLDN/AP, PVJD-LDN/AP, PVJDLDV, PVJD-LDV, PVJDLDV/AP, PVJD-LDV/AP, PVJDLEN, PVJD-LEN, PVJDLEN/AP, PVJD-LEN/AP, PVJDLEV, PVJD-LEV, PVJDLEV/AP, PVJD-LEV/AP, PVJDLHN, PVJD-LHN, PVJDLHN/AP, PVJD-LHN/AP, PVJDLHV, PVJD-LHV, PVJDLHV/AP, PVJD-LHV/AP, PVJDLJN, PVJD-LJN, PVJDLJN/AP, PVJD-LJN/AP, PVJDLJV, PVJD-LJV, PVJDLJV/AP, PVJD-LJV/AP, PVJDLWN, PVJD-LWN, PVJDLWN/AP, PVJD-LWN/AP, PVJDLWV, PVJD-LWV, PVJDLWV/AP, PVJD-LWV/AP