Hydnet - the specialist in intelligent hydraulic systems
Contact
PVDD

Pressure reducing/relieving valve from Sun Hydraulics

Description

Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

Read more ▼
  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-21A
Series 1
Capacity 10 gpm
Capacity (metric) 40 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Factory Pressure Settings Established at blocked control port (dead headed)
Control Pilot Flow 7 – 10 in³/min.
Control Pilot Flow (metric) 0,11 – 0,16 L/min.
Adjustment – No. of CW Turns from Min. to Max. setting 5
Valve Hex Size 7/8 in.
Valve Hex Size (metric) 22,2 mm
Valve Installation Torque 30 – 35 lbf ft
Valve Installation Torque (metric) 41 – 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.
Adjustment Screw Internal Hex Size (metric) 4 mm
Locknut Hex Size 9/16 in.
Locknut Hex Size (metric) 15 mm
Locknut Torque 80 – 90 lbf in.
Locknut Torque (metric) 9 – 10 Nm
Model Weight 0.41 lb.
Model Weight (metric) 0.19 kg.
Seal kit – Cartridge Viton: 990021006

Configuration Options

Control

C Tamper Resistant – Factory Set
K Handknob
L Standard Screw Adjustment

Adjustment Range

A 100 – 3000 psi (7 – 210 bar), 200 psi (14 bar) Standard Setting
B 50 – 1500 psi (3,5 – 105 bar), 200 psi (14 bar) Standard Setting
D 25 – 800 psi (1,7 – 55 bar), 200 psi (14 bar) Standard Setting
E 25 – 400 psi (1,7 – 28 bar), 200 psi (14 bar) Standard Setting
W 150 – 4500 psi (10,5 – 315 bar), 200 psi (14 bar) Standard Setting
N 60 – 800 psi (4 – 55 bar), 200 psi (14 bar) Standard Setting
Q 60 – 400 psi (4 – 28 bar), 200 psi (14 bar) Standard Setting

Seal Material

N Buna-N
V Viton
Cavity: T-21A
Nominal Capacity: 40 lpm (10 gpm)
Downloads
PDF
Possible variants

PVDDCAN, PVDD-CAN, PVDDCAV, PVDD-CAV, PVDDCBN, PVDD-CBN, PVDDCBV, PVDD-CBV, PVDDCDN, PVDD-CDN, PVDDCDV, PVDD-CDV, PVDDCEN, PVDD-CEN, PVDDCEV, PVDD-CEV, PVDDCNN, PVDD-CNN, PVDDCNV, PVDD-CNV, PVDDCQN, PVDD-CQN, PVDDCQV, PVDD-CQV, PVDDCWN, PVDD-CWN, PVDDCWV, PVDD-CWV, PVDDKAN, PVDD-KAN, PVDDKAV, PVDD-KAV, PVDDKBN, PVDD-KBN, PVDDKBV, PVDD-KBV, PVDDKDN, PVDD-KDN, PVDDKDV, PVDD-KDV, PVDDKEN, PVDD-KEN, PVDDKEV, PVDD-KEV, PVDDKNN, PVDD-KNN, PVDDKNV, PVDD-KNV, PVDDKQN, PVDD-KQN, PVDDKQV, PVDD-KQV, PVDDKWN, PVDD-KWN, PVDDKWV, PVDD-KWV, PVDDLAN, PVDD-LAN, PVDDLAV, PVDD-LAV, PVDDLBN, PVDD-LBN, PVDDLBV, PVDD-LBV, PVDDLDN, PVDD-LDN, PVDDLDV, PVDD-LDV, PVDDLEN, PVDD-LEN, PVDDLEV, PVDD-LEV, PVDDLNN, PVDD-LNN, PVDDLNV, PVDD-LNV, PVDDLQN, PVDD-LQN, PVDDLQV, PVDD-LQV, PVDDLWN, PVDD-LWN, PVDDLWV, PVDD-LWV