Hydnet - the specialist in intelligent hydraulic systems
Contact
LPJA

Modulating element from Sun Hydraulics

Description

These normally open modulating elements with an internal orifice between port 1 and port 3 can be used as a main-stage reducing valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.

Read more ▼
  • A tuning adjustment (models configured with an L control) is available to vary the pressure drop across the compensator to increase/decrease flow within +/-25% of setting.
  • All ports will accept 5000 psi (350 bar).
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Technical Data

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity T-19A
Series 4
Capacity 120 gpm
Capacity (metric) 480 L/min.
Maximum Operating Pressure 5000 psi
Maximum Operating Pressure (metric) 350 bar
Control Pilot Flow 15 – 30 in³/min.
Control Pilot Flow (metric) 0,25 – 0,50 L/min.
Control Orifice Diameter .021 in.
Control Orifice Diameter (metric) 0,53 mm
Valve Hex Size 1 5/8 in.
Valve Hex Size (metric) 41,3 mm
Valve Installation Torque 350 – 375 lbf ft
Valve Installation Torque (metric) 474 – 508 Nm
Seal kit – Cartridge Viton: 990019006
Model Weight 2.57 lb.
Model Weight (metric) 1.17 kg.

Configuration Options

Control

L Tuning Adjustment
X Not Adjustable

Bias Pressure

D 50 psi (3,5 bar)
F 100 psi (7 bar)
G 150 psi (10,5 bar)
H 200 psi (14 bar)

Seal Material

N Buna-N
V Viton
E EPDM

Material/Coating

/AP Stainless Steel, Passivated
Cavity: T-19A
Nominal Capacity: 120 gpm (480 lpm )
Downloads
PDFSTP
Possible variants

LPJA8DE, LPJA-8DE, LPJA8DN, LPJA-8DN, LPJA8DV, LPJA-8DV, LPJALDE, LPJA-LDE, LPJALDN, LPJA-LDN, LPJALDV, LPJA-LDV, LPJAXDE, LPJA-XDE, LPJAXDN, LPJA-XDN, LPJAXDN/AP, LPJA-XDN/AP, LPJAXDV, LPJA-XDV, LPJAXDV/AP, LPJA-XDV/AP, LPJAXFE, LPJA-XFE, LPJAXFN, LPJA-XFN, LPJAXFN/AP, LPJA-XFN/AP, LPJAXFV, LPJA-XFV, LPJAXFV/AP, LPJA-XFV/AP, LPJAXGE, LPJA-XGE, LPJAXGN, LPJA-XGN, LPJAXGN/AP, LPJA-XGN/AP, LPJAXGV, LPJA-XGV, LPJAXGV/AP, LPJA-XGV/AP, LPJAXHE, LPJA-XHE, LPJAXHN, LPJA-XHN, LPJAXHN/AP, LPJA-XHN/AP, LPJAXHV, LPJA-XHV, LPJAXHV/AP, LPJA-XHV/AP