Modulating element from Sun Hydraulics
Normally open modulating elements without an internal orifice act as a restrictive compensator to maintain a constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 120 gpm |
| Capacity (metric) | 480 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Valve Hex Size | 1 5/8 in. |
| Valve Hex Size (metric) | 41,3 mm |
| Valve Installation Torque | 350 – 375 lbf ft |
| Valve Installation Torque (metric) | 474 – 508 Nm |
| Seal kit – Cartridge | Viton: 990019006 |
Control
| P | External 1/4 NPTF Pilot Port, Port 3 Blocked |
| X | Not Adjustable |
Differential Pressure
| D | 50 psi (3,5 bar) |
| F | 100 psi (7 bar) |
| G | 150 psi (10,5 bar) |
| H | 200 psi (14 bar) |
Seal Material
| N | Buna-N |
| V | Viton |
| E | EPDM |
Material/Coating
| /AP | Stainless Steel, Passivated |
| /LH | Mild Steel, Zinc-Nickel |