Load holding valve from Sun Hydraulics.
Balanced load control valves combine a balanced modulating element with a reverse flow check. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulating element controls flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting.
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 120 gpm |
| Capacity (metric) | 480 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Maximum Valve Leakage at Reseat | See Technical Features |
| Check Cracking Pressure | 25 psi |
| Check Cracking Pressure (metric) | 1,7 bar |
| Valve Hex Size | 1 5/8 in. |
| Valve Hex Size (metric) | 41,3 mm |
| Valve Installation Torque | 350 – 375 lbf ft |
| Valve Installation Torque (metric) | 474 – 508 Nm |
| Model Weight | 4.19 lb. |
| Model Weight (metric) | 1.90 kg. |
Control
| X | Not Adjustable |
Minimum Control Pressure
| E | 75 psi (5 bar) |
| G | 100 psi (7 bar) |
| H | 200 psi (14 bar) |
| I | 300 psi (20 bar) |
| K | 450 psi (33 bar) |
| M | 525 psi (36,7 bar) |
Seal Material
| N | Buna-N |
| V | Viton |
| E | EPDM |
Material/Coating
| /AP | Stainless Steel, Passivated |