Load holding valve from Sun Hydraulics.
Description
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamber references the vent (port 4).
Read more ▼
- The maximum recommended load pressure for the K range is 2310 psi (159 bar). The cracking pressure for the K range will be 2880-3715 psi (199-256 bar).
- The maximum recommended load pressure for the L range is 3080 psi (212 bar). The cracking pressure for the L range will be 3880-4815 psi (268-332 bar).
- The maximum recommended load pressure for the M range is 3850 psi (265 bar). The cracking pressure for the M range will be 4880-5815 psi (336-401 bar).
- Note: The pressures listed under RANGE are approximate, mean values and should not be used for inspection purposes.
- Note: The percentage difference between the cracking and reseat values for the fixed and adjustable versions are identical. However, the cracking point for the adjustable control can be set via the adjustment mechanism to within +/- 15 psi (1 bar) or +/- 2.5% of setting (whichever is greater) of the specified value. In the case of the fixed version, the setting tolerance can only be maintained within a +/- 470-psi (32-bar) range. Thus for the 3000-psi (210-bar) fixed-setting model, with a rising pressure the valve will open below 3715 psi (256 bar) and with a falling pressure will reseat above 2310 psi (159 bar). For the 4000-psi (275-bar) fixed-setting model, with a rising pressure the valve will open below 4815 psi (332 bar) and with a falling pressure will reseat above 3080 psi (212 bar). For the 5000-psi (350-bar) fixed-setting model, with a rising pressure the valve will open below 5815 psi (401 bar) and with a falling pressure will reseat above 3850 psi (265 bar).
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Fixed-setting load control valves can be used to protect cylinder seals in outrigger circuits from damage due to thermal expansion, however, they probably should not be applied in circuits in which a matched valve setting may be required such as dual cylinder applications.
- Fixed-setting load control valves offer a shorter cartridge extension than the adjustable version.
- These valves are capable of modulating over a broader range of flows than the pure poppet designs. The longer stroke allows us to incorporate a uni-directional damping
Technical Data
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity |
T-24A |
| Series |
4 |
| Capacity |
120 gpm |
| Capacity (metric) |
480 L/min. |
| Maximum Operating Pressure |
5000 psi |
| Maximum Operating Pressure (metric) |
350 bar |
| Pilot Ratio |
4.5:1 |
| Maximum Recommended Load Pressure |
See Technical Features |
| Factory Pressure Settings Established at |
2 in³/min. |
| Factory Pressure Settings Established at (metric) |
30 cc/min. |
| Maximum Valve Leakage at Reseat |
5 drops/min. |
| Maximum Valve Leakage at Reseat (metric) |
0,3 cc/min. |
| Check Cracking Pressure |
25 psi |
| Check Cracking Pressure (metric) |
1,7 bar |
| Reseat |
≥77% of setting |
| Valve Hex Size |
1 5/8 in. |
| Valve Hex Size (metric) |
41,3 mm |
| Valve Installation Torque |
350 – 375 lbf ft |
| Valve Installation Torque (metric) |
474 – 508 Nm |
| Seal kit – Cartridge |
Viton: 990024006 |
| Model Weight |
4.20 lb. |
| Model Weight (metric) |
1.91 kg. |
Configuration Options
Factory Set
| K |
3000 psi (210 bar) |
| L |
4000 psi (280 bar) |
| M |
5000 psi (350 bar) |
Seal Material
Material/Coating
| /AP |
Stainless Steel, Passivated |
| /LH |
Mild Steel, Zinc-Nickel |