Load holding valve from Sun Hydraulics.
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamber references the vent (port 4).
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-23A |
| Series | 3 |
| Capacity | 60 gpm |
| Capacity (metric) | 240 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Pilot Ratio | 4.5:1 |
| Maximum Recommended Load Pressure | See Technical Features |
| Factory Pressure Settings Established at | 2 in³/min. |
| Factory Pressure Settings Established at (metric) | 30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min. |
| Maximum Valve Leakage at Reseat (metric) | 0,3 cc/min. |
| Check Cracking Pressure | 25 psi |
| Check Cracking Pressure (metric) | 1,7 bar |
| Adjustment – No. of CCW Turns from Min. to Max. Setting | 9 |
| Reseat | ≥77% of setting |
| Valve Hex Size | 1 1/4 in. |
| Valve Hex Size (metric) | 31,8 mm |
| Valve Installation Torque | 150 – 160 lbf ft |
| Valve Installation Torque (metric) | 203 – 217 Nm |
| Seal kit – Cartridge | Viton: 990023006 |
| Model Weight | 2.08 lb. |
| Model Weight (metric) | 0.94 kg. |
Control
| L | Standard Screw Adjustment |
Functional Setting Range
| H | 1000 – 4000 psi (70 – 280 bar), 3000 psi (210 bar) Standard Setting |
| J | 2000 – 5000 psi (140 – 350 bar), 3000 psi (210 bar) Standard Setting |
Seal Material
| N | Buna-N |
| V | Viton |