Priority flow control valve from Sun Hydraulics
This valve is a fixed-orifice, non-pressure-compensated flow control with a reverse flow check. The flow setting is specified by the user and is set at the factory.
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-5A |
| Series | 2 |
| Capacity | 30 gpm |
| Capacity (metric) | 120 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Orifice Range | .016 – .135 in. |
| Orifice Range (metric) | 0,4 – 3,4 mm |
| Valve Hex Size | 1 1/8 in. |
| Valve Hex Size (metric) | 28,6 mm |
| Valve Installation Torque | 45 – 50 lbf ft |
| Valve Installation Torque (metric) | 61 – 68 Nm |
| Seal kit – Cartridge | Viton: 990203006 |
Control
| X | Not Adjustable |
Setting Range
| A | 4 psi (0,3 bar) Cracking Pressure, .016 – .135 in. (0,4 – 3,4 mm) |
| B | 15 psi (1 bar) Cracking Pressure, .016 – .135 in. (0,4 – 3,4 mm) |
| C | 30 psi (2 bar) Cracking Pressure, .016 – .135 in. (0,4 – 3,4 mm) |
| D | 50 psi (3,5 bar) Cracking Pressure, .016 – .135 in. (0,4 – 3,4 mm) |
| E | 75 psi (5 bar) Cracking Pressure, .016 – .135 in. (0,4 – 3,4 mm) |
| F | 100 psi (7 bar) Cracking Pressure, .016 – .135 in. (0,4 – 3,4 mm) |
| Z | 1 psi (0,07 bar) Cracking Pressure, .016 – .135 in. (0,4 – 3,4 mm) |
Seal Material
| N | Buna-N |
| V | Viton |
Material/Coating
| /AP | Stainless Steel, Passivated |