Priority flow control valve from Sun Hydraulics
This valve is a fixed-orifice, non-pressure-compensated flow control with a reverse flow check. The flow setting is specified by the user and is set at the factory.
Note: Data may vary by configuration. See CONFIGURATION section.
| Cavity | T-162A |
| Series | 0 |
| Capacity | 7.5 gpm |
| Capacity (metric) | 30 L/min. |
| Maximum Operating Pressure | 5000 psi |
| Maximum Operating Pressure (metric) | 350 bar |
| Orifice Range | .016 – .062 in. |
| Orifice Range (metric) | 0,4 – 1,6 mm |
| Valve Hex Size | 3/4 in. |
| Valve Hex Size (metric) | 19,1 mm |
| Valve Installation Torque | 20 – 25 lbf ft |
| Valve Installation Torque (metric) | 27 – 33 Nm |
| Model Weight | 0.17 lb. |
| Model Weight (metric) | 0.08 kg. |
| Seal kit – Cartridge | Viton: 990162006 |
Control
| X | Not Adjustable |
Setting Range
| A | 4 psi (0,3 bar) Cracking Pressure, .016 – .062 in. (0,4 – 1,6 mm) |
| C | 30 psi (2 bar) Cracking Pressure, .016 – .062 in. (0,4 – 1,6 mm) |
| E | 75 psi (5 bar) Cracking Pressure, .016 – .062 in. (0,4 – 1,6 mm) |
Seal Material
| N | Buna-N |
| V | Viton |
Material/Coating
| /AP | Stainless Steel, Passivated |
| /LH | Mild Steel, Zinc-Nickel |